CAUTION: Before commencing the works, you should make sure that the power supply cable is not live.
• Measure and create an opening in an external wall for the telescopic duct of the device.
CAUTION: The diameter of the opening should be at least 10 mm larger compared to the external
diameter of the duct.
• Place the telescopic duct (4) together with the exchanger (7) and lter (6) in the external wall and seal with
foam or cotton wool.
The duct should be mounted in such a way that it is slightly de ected towards the outside. The exchanger
together with the lter should be located at least 10 cm away from the edge of the telescopic duct.
• Insert the end of the duct (5) in the telescopic duct and than fasten it to the wall with the use of mounting
pins.
• Remove the front panel of the fan (1) and the cover of electronics (2).
• Drag the electric cable in double insulation through the cable grommet. Move the cable until it is possible to
connect it to power supply clamps.
Before fastening the fan: remove the foreign objects from the inside of the fan; check, whether the rotor
rotates freely by making it move with your hand.
• Insert the fan (3) into telescopic duct and than fasten it to the wall with the use of mounting pins.
CAUTION: The grommet of the cable should be located at the bottom.
• Remove the external insulation from the cable, remove the insulation from the wires over 4 mm.
• Place the cable and connect it in accordance with the connections scheme of the installed model.
• Check whether the conductors of the cable are strongly connected to the clamps.
• Check whether the fan is fastened in a solid manner and the electric wiring system is proper.
• Put on and screw the cover of electronics (2).
• Check the sealing of the connection cable.
- The connection cable must be secured in a way ensuring that in the case of ooding, no water ows along
the cable to the live parts.
• Mount the front panel (1) constituting the protection against contact with the moving parts.
ATTENTION! A rotating impeller can crush your ngers! It is forbidden to start the fan
without a protective mesh against touching the moving parts!
The rst activation
The activation may take place only after all safety instructions had been checked and all dangers had been
eliminated. After activation, check whether the fan works normally and whether the air ows in a proper manner.
Observe the work of the fan (its loudness, vibrations, consumption of electricity, the possibility to control the
rotational speed).
The device may be used only with the front panel and the end of the duct constituting the protection against the
contact with the moving parts. The user is responsible for meeting the present norms and may bear the
responsibility for the accidents resulting from the lack of protection elements.
Connecting to power supply
• Only quali ed electricians may connect the fan to power supply and activate it for the rst time.
• The adequate norms, safety provisions and technical conditions for the connections of the enterprise
providing the electricity should be strictly followed!
• In this case, it is necessary to use mains multi-polar switch/isolation switch with a minimum 3 mm opening of a
contact (PN-EN 60335-1)!
• The types of mains, voltage and frequencies have to be compliant with the data on the rating plate.
Dimensions
The dimensions of particular models have been presented in the gures: 5a and 5b.
MAINTENANCE AND CLEANING
Keeping the fan operational, maintenance
• During maintenance, you should use protective shoes and protective gloves!