2.8. Safety

2.8.1. Alarms and alerts

DEFAULT
SAFETY
CONFIGURATION
Alarms
Activated
Alert
Activated
* The corresponding alarm or alert is maintained while the detected fault remains in place, and the corresponding
message reappears a few moments after dismissal.
Message
displayed/Fault
detected
pH corrector container
Problem with empty pH
Insufficient water flow
Flow sensor problem
Series of 5 unsuccessful
attempts to correct the pH
pH probe incorrectly
IMMEDIATE AND AUTOMATIC OPERATIONS ON
Specific display
Possible cause
empty
container sensor
calibrated
pH sensor problem
ACTIVATION
Stop pH regulation
Yes
No
Checks and solutions
Replace the pH corrector container.
Check:
- the connection of the sensor to the electronics
unit.
- the condition of the sensor, including the cable.
Check that:
- the valves on the filtration circuit are open.
- the filter pump is working properly.
- the filtration circuit is not blocked.
- there is enough water in the pool.
Check:
- the connection of the sensor to the electronics
unit.
- the condition of the sensor, including the cable.
Ensure the pH corrector container is not empty.
Check the condition:
- filter with ballast.
- semi-rigid pipes.
- of the peristaltic pump.
- injection connector.
Carry out a manual injection.
Check that:
- the peristaltic pump is working properly.
- the pH corrector is correctly injected.
menus.
Calibrate the pH probe.
Calibrate the pH probe.
Check:
- the connection of the probe to the electronics unit.
- the condition of the probe, including the cable.
DISMISSAL*
Press the OK or
button (press
or press and hold, depending on
whether it is an alarm or alert).
Can be
disabled via
(if the empty pH
container sensor is
activated)
menu
Yes
No
Yes
Yes
11