Electrical connection

Window contact switch

16
The window contact switch connects to
the right hand terminal a on the control
module.
When the window is closed (window
contact switch open) the cooker hood
fan cannot be switched on. The On/Off
button indicator light on the cooker
hood will flash.
The cooker hood fan can only be
switched on when the window is open
(window contact switch closed) and
sufficient air can be drawn into the
room.
The same applies to operation with an
external fan motor.
The cooker lighting is not affected by
this.
The connection cable between the
window contact switch and the cooker
hood must not exceed 25 m.