7. Checklist for installing HVI
If all questions in the below checklist are answered with "yes", it can be assumed that the HVI
Conductor is installed correctly. The checklist can be downloaded from the Download section of our
homepage.
Checklist for HVI
Address of the test object:
Name _____________________________________________________________________________________
Contact partner ______________________________________________________________________________
Postcode, Place, Street _________________________________________________________________________
Phone _____________________________________________________________________________________
Item
1
Is the whole system positioned in the protected area of the isolated air-termination
system?
2
Has the separation distance been calculated?
(down conductor to the earth-termination system, isolated system with connec-
tion to existing external lightning protection system or lightning equipotential
bonding on roof level)
3
Is the maximum equivalent separation distance specified by DEHN + SÖHNE for
the application of the HVI
HVI
®
light Conductor / DEHNcon H
HVI
®
Conductor
HVI
power Conductor
®
4
Is the calculated separation distance kept in the range of the sealing end?
5
Is the supporting tube and, if required, the equipotential bonding element of the
sealing end correct, i.e. only connected with the equipotential bonding / the light-
ning equipotential bonding of the system?
6
Is the minimum distance of 0.2 m kept between HVI
lel and has the connection to opposite down conductors been considered?
7
Has the minimum bending radius been kept?
HVI
light Conductor (dark grey outer coating)
®
HVI
Conductor (black outer coating)
®
HVI
Conductor (grey outer coating)
®
HVI
power Conductor (black outer coating)
®
8
Is the equipotential bonding element of the sealing end in contact with the semi-
conductive layer (not grey coating)?
9
Has the supplementary information of the DEHN installation instructions No. 1501
been considered for the installation of the HVI
__________________________________
Place
______________________________________________________________
Figure 15 Checklist
Installation
®
Question
Conductor kept?
®
s ≤ 0.45 m in air
s ≤ 0.75 m in air
s ≤ 0.9 m in air
Conductor in hazardous areas?
®
_________________________
Date
Signature of tester
Conductors
®
s ≤ 0.9 m solid material
s ≤ 1.5 m solid material
s ≤ 1.8 m solid material
Conductors routed in paral-
®
200 mm
200 mm
230 mm
270 mm
Company
Rating
YES
NO
power
®
31