Product Specifications - nemaxx HW-2 Original-Gebrauchsanleitung

Rauch- und hitzewarnmelder
Inhaltsverzeichnis

Werbung

Thank you for purchasing our wireless smoke and heat detector.
Please take a few minutes to read the user's manual thoroughly and familiarize yourself and your
family with its operation.
And save it for future reference.

PRODUCT SPECIFICATIONS

• POWER: DC2*1.5VAlkalineAA battery
(Gold Peak Group: GP 15A LR6 or Energize: E91)
• OPERATION CURRENT: <4uA (standby), <40mA (alarm)
• ALARM VOLUME: >85dB(A) at 3 meters.
• SMOKE SENSITIVITY: 0.122-0.189dB/m
• HEAT SENSITIVITY: 54-70
• LOCAL SMOKE ALARM SOUND PATTERN:
BI 0.5s - pause 0.5s – BI 0.5s – pause 0.5s – BI 0.5s – pause 1.5s,
with the red LED flash, repeat this alarm pattern.
• LOCAL HEAT ALARM SOUND PATTERN:
BI 0.2s - pause 0.1s, with the red LED flash, repeat this alarm pattern.
• WIRELESS ALARM SOUND PATTERN:
Bi - Bi - pause 1.2s, with the red LED flash, repeat this alarm pattern.
• COMPLY WITH: EN14604:2005/AC-2008
DESCRIPTION
The unit is a photoelectric 3V DC smoke alarm. It is operated by 3V AA Alkaline battery.
With the photoelectric technology, it is more sensitive to detecting slow smoldering fires
which general thick, black smoke, little heat that may smolder for hours before bursting into
flames. The smoke alarm does not contain the radioactive material which is harmful to the
environment. The smoke alarm should be installed in every room (except the bathroom),
and every other area of the home, making sure the people in the home will be able to hear
and respond to the alarm sound.
For minimum protection you should fit an alarm in the hallway between the living areas and
sleeping areas.
Place the unit as close to the living areas as possible and ensure the alarm is audible when
the bedrooms are occupied.
Recommendation for a typical single story home:
Install a smoke alarm on the ceiling inside each bedroom and in the hallway outside each
separate sleeping area.
If a bedroom area hallway is more than 30 feet long, install a smoke alarm at each end of
the hallway. If there is a basement, install a smoke alarm on the basement ceiling at the
bottom of the stairwell.
Recommendation for a typical multi-story home:
Install a smoke alarm on the ceiling inside each bedroom and in the hallway outside each
separate sleeping area.
If a bedroom area hallway is more than 30 feet long, install a smoke alarm at each end
install a smoke alarm at the top of a first – to- second floor stairwell.