Herunterladen Diese Seite drucken

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
XMS Handbook
ENGLISH
General Safety Instructions:
READ SAFETY INSTRUCTIONS
Servicing:
These products are not customer serviceable TDK-Lambda UK LTD and their authorised agents only are permitted
to carry out repairs.
Critical Components:
These products are not authorised for use as critical components in nuclear control systems, life support systems or
equipment for use in hazardous environments without the express written approval of the Managing Director of TDK-
Lambda EMEA.
Product Usage:
These products are designed for use within a host equipment which restricts access to authorised competent
personnel.
This product is a component power supply and is only to be installed by qualified persons within other equipment and
must be not operated as a stand alone product.
This product is for sale to business to business customers and can be obtained via distribution channels.
It is not intended for sale to end users.
This product is a component power supply and does not fall within the scope of the EMC directive. Compliance with
the EMC directive must be considered in the final installation.. Please contact your local TDK-Lambda office
Environmental:
These products are IPX0, and therefore chemicals/solvents, cleaning agents and other liquids must not be used.
Environment:
This power supply is a switch mode power supply for use in applications within a Pollution Degree 2, overvoltage
category II environment. Material Group IIIb PCB's are used within it.
Output Loading:
The output power taken from the power supply must not exceed the rating stated on the power supply label, except
as stated in the product limitations in this handbook.
Input Parameters:
This product must be operated within the input parameters stated in the product limitations in this handbook.
End of Life Disposal:
The unit contains components that require special disposal. Make sure that the unit is properly disposed of at the
end of its service life and in accordance with local regulations.
RISK OF ELECTRIC SHOCK
High Voltage Warning:
Dangerous voltages are present within the power supply. The professional installer must protect service personnel
from inadvertent contact with these dangerous voltages in the end equipment.
WARNING: When installed in a Class 1 end equipment, this product must be reliably earthed and professionally
installed.
When installed in a Class II end equipment, no earthing connection to the power supply is required.
CAUTION: DOUBLE POLE/NEUTRAL FUSING
The (+) or (-) output(s) can be earthed or left floating.
Page 1 of 24
260217 issue 10, May 2018

Werbung

loading

Inhaltszusammenfassung für TDK-Lambda XMS500KB

  • Seite 1 General Safety Instructions: READ SAFETY INSTRUCTIONS Servicing: These products are not customer serviceable TDK-Lambda UK LTD and their authorised agents only are permitted to carry out repairs. Critical Components: These products are not authorised for use as critical components in nuclear control systems, life support systems or equipment for use in hazardous environments without the express written approval of the Managing Director of TDK- Lambda EMEA.
  • Seite 2 Internal fuses protect the unit and must not be replaced by the user. In case of internal defect, the unit must be returned to TDK-Lambda UK LTD or one of their authorised agents. A suitable mechanical, electrical and fire enclosure must be provided by the end use equipment for mechanical, electric shock and fire hazard protection.
  • Seite 3: Gefahr Durch Elektrischen Schlag

    Allgemeine Sicherheitsvorschriften: LESEN SIE DIE SICHERHEITSVORSCHRIFTEN Wartung: Diese Produkte können nicht durch den Kunden gewartet werden. Nur TDK-Lambda UK LTD. und deren zugelassene Vertriebshändler sind zur Durchführung von Reparaturen berechtigt. Kritische Komponenten: Diese Produkte sind nicht für die Verwendung als kritische Komponenten in nuklearen Kontrollsystemen, Lebenserhaltungssystemen oder Geräten in gefährlichen Umgebungen geeignet, sofern dies nicht ausdrücklich und...
  • Seite 4 Für ummantelt Produkte, verwenden Sie keine Schrauben, die das Gerät mehr als durchdringen; siehe Zeichnung Eine interne Sicherung schützt das Gerät und darf durch den Benutzer nicht ausgetauscht werden. Im Fall von internen Defekten muss das Gerät an TDK-Lambda UK LTD oder einen der autorisierten Vertriebshändler zurückgeschickt werden.
  • Seite 5 Consignes générales de sécurité: LIRE LES CONSIGNES DE SECURITE Entretien: Ces produits ne peuvent pas être réparés par l’utilisateur. Seuls, TDK-Lambda UK LTD et ses agents agréés sont autorisés à effectuer des réparations. Composants critiques: Ces produits ne doivent pas être utilisés en tant que composants critiques dans des systèmes de commande nucléaire, dans des systèmes de sauvetage ou dans des équipements utilisés dans des environnements dangereux,...
  • Seite 6 Un fusible interne protège le module et ne doit pas être remplacé par l'utilisateur. En cas de défaut interne, le module doit être renvoyé à TDK-Lambda UK LTD ou l'un de ses agents agréés. Une enceinte appropriée doit être prévue par l'utilisateur final pour assurer la protection contre les chocs mécaniques, les chocs électriques et l'incendie.
  • Seite 7: Rischio Di Scossa Elettrica

    Manutenzione: Il cliente non può eseguire alcuna manutenzione su questi prodotti. L'esecuzione delle eventuali riparazioni è consentita solo a TDK-Lambda UK LTD e ai suoi agenti autorizzati. Componenti critici: Non si autorizza l'uso di questi prodotti come componenti critici all'interno di sistemi di controllo nucleari, sistemi necessari alla sopravvivenza o apparecchiature destinate all'impiego in ambienti pericolosi, senza l'esplicita approvazione scritta dell'Amministratore Delegato di TDK-Lambda EMEA.
  • Seite 8 Un fusibile interno protegge l'unità e non deve essere sostituito dall'utente. Nell'eventualità di un difetto interno, restituire l'unità a TDK-Lambda UK LTD o a uno dei suoi agenti autorizzati. L'apparecchiatura finale deve includere una recinzione meccanica, elettrica e antincendio per proteggere dai pericoli di natura meccanica, dalle scosse elettriche e dai pericoli di incendio.
  • Seite 9: Peligro De Descargas Eléctricas

    Instrucciones generales de seguridad: LEA LAS INSTRUCCIONES DE SEGURIDAD Servicio: Estos productos no pueden ser reparados por los clientes. TDK-Lambda UK LTD. y sus agentes autorizados son los únicos que pueden llevar a cabo las reparaciones. Componentes fundamentales: Estos productos no pueden ser utilizados como componentes fundamentales en sistemas de control nuclear, sistemas de soporte vital o equipos a utilizar en entornos peligrosos sin el consentimiento expreso por escrito del Director General de TDK-Lambda EMEA.
  • Seite 10 Un fusible interno protege la unidad y este no debe ser nunca reemplazado por el usuario. En caso de existir algún defecto interno, la unidad debe ser enviada a TDK-Lambda UK LTD o a uno de sus agentes autorizados. El equipo de uso final debe constituir un recinto de protección mecánica, eléctrica y contra incendios de protección mecánica, contra descargas eléctricas y contra el peligro de incendios.
  • Seite 11 Instruções gerais de segurança: LEIA AS INSTRUÇÕES DE SEGURANÇA Manutenção: Estes produtos não são podem ser submetidos a manutenção por parte do cliente. Apenas a TDK-Lambda UK LTD e os seus agentes autorizados têm permissão para realizar reparações. Componentes essenciais: Não é...
  • Seite 12 Existe um fusível interno que protege a unidade e que não deve ser substituído pelo utilizador. Em caso de defeito interno, a unidade deve ser devolvida à TDK-Lambda UK LTD ou a um dos seus agentes autorizados. O equipamento de utilização final deve fornecer um bastidor com protecção mecânica, eléctrica e contra incêndios adequada.
  • Seite 13 XMS Handbook Special Instructions for medical applications IEC/EN 60601-1 2nd Edition UL 60601-1 1st Edition CSA-C22.2 No. 601.1-M90 IEC/EN 60601-1 3rd Edition ANSI/AAMI ES 60601-1 CSA C22.2 No 60601-1  These products are designed for continuous operation within an overall enclosure, and must be mounted such that access to the mains terminals is restricted.
  • Seite 14 XMS Handbook Environmental Specifications: Description Operation Storage & Transportation Indoor Temperature 0°C to +50°C -40°C to +70°C Humidity 5 - 95% RH, non-condensing 5 - 95% RH, non-condensing Altitude -200m to 5000m* -200m - 5000m Pressure 54kPa (5000m)* - 106kPa 54kPa - 106kPa Orientation The unit may be mounted in any orientation except...
  • Seite 15 XMS Handbook Unit Nomenclature XMS or XMS models as described below: Units may be marked with a Product Code: Xy where y may be any number of characters. Unit Configuration (Description) Code may be prefixed by NS # followed by / or - (where # may be any number of characters indicating non- safety related model differences).
  • Seite 16 XMS Handbook Input Parameters Standard 60601-1 60950-1 Nominal input voltage 100 - 240 Vac 100 - 240 Vac Input voltage range 90 - 264Vac 90 - 264Vac Input frequency range 47 - 63Hz 47 - 63Hz Maximum input current 7A (5.3A*) rms 7A (5.3A*) rms * Input for 350W models.
  • Seite 17 XMS Handbook Output Limitations All outputs are SELV. Channel 1 is hazardous energy Input Connections: Molex KK type 3 pin (2 pin for XMSxD models) header: 7A/250V Max. Cooling for units with customer supplied air (all models except –KF and TF) The following method must be used for determining the safe operation of PSUs.
  • Seite 18 XMS Handbook Component Layout Drawing Class I only ASY5 Page 18 of 24 260217 issue 10, May 2018...
  • Seite 19 XMS Handbook XMS Uncased, Outline and Connections Class I A 4 OFF HOLES Ø 3.5mm CLEARANCE FOR M3 FIXINGS. ALL TOLERANCES +/-0.5mm. MATING PARTS (MOLEX OR EQUIVALENT CONNECTOR HOUSING CRIMP PIN CONNECTION 09-50-8051 08-52-0113 Live 90142-0008 90119-0109 NOT CONNECTED 51191-0200 50802-9001 NEUTRAL NOT CONNECTED...
  • Seite 20 XMS Handbook XMS Uncased, Outline and Connections Class II A 4 OFF HOLES Ø 3.5mm CLEARANCE FOR M3 FIXINGS. ALL TOLERANCES +/-0.5mm. MATING PARTS (MOLEX OR EQUIVALENT CONNECTOR HOUSING CRIMP PIN CONNECTION 09-50-1031 08-70-1030 L Live 90142-008 90119-0109 NOT CONNECTED 51191-0200 50802-9001 NEUTRAL...
  • Seite 21 XMS Handbook XMS U chassis (non-standard) with Molex KK Type Input Connector, Outline. B 4 OFF FIXING HOLES FOR M3 MAXIMUM PENETRATION 3mm ALL TOLERANCES +/-0.5mm. MAXIMUM TORQUE 0.5-0.6Nm Page 21 of 24 260217 issue 10, May 2018...
  • Seite 22 XMS Handbook XMS S Chassis (standard) Outline. C 2 OFF FIXING HOLES FOR M3 MAXIMUM PENETRATION OF 3MM D 4 OFF FIXING HOLES FOR M3 MAXIMUM PENETRATION 2.4mm ALL TOLERANCES +/-0.5mm. MAXIMUM TORQUE 0.5-0.6Nm Page 22 of 24 260217 issue 10, May 2018...
  • Seite 23 XMS Handbook KF Non Standard Top Fan Cover A 2 OFF FIXING HOLES FOR M3 MAXIMUM PENETRATION: 3MM ALL TOLERANCES +/-0.5mm. MAXIMUM TORQUE 0.5-0.6Nm Page 23 of 24 260217 issue 10, May 2018...
  • Seite 24 C 2 OFF FIXING HOLES FOR M3 MAXIMUM PENETRATION OF 3MM D 4 OFF FIXING HOLES FOR M3 MAXIMUM PENETRATION 2.4mm ALL TOLERANCES +/-0.5mm. MAXIMUM TORQUE 0.5-0.6Nm TDK-Lambda UK Ltd Kingsley Avenue, Ilfracombe Devon, EX34 8ES Telephone - Sales and Service +44 (0)1271 856666 Head Office and Works +44 (0)1271 856600...