GB
1. About this document
– Under copyright. Reproduction either in whole or
in part only with our consent.
– Subject to change in the interest of technical
progress.
– All product dimensions in mm.
2. General safety precautions
Failure to observe these operating
!
instructions presents hazards!
These instructions contain important information on
the safe use of this product. Particular attention is
drawn to potential hazards. Failure to observe this
information may lead to death or serious injuries.
• Read instructions carefully.
• Follow safety advice.
• Keep instructions within easy reach.
– Working with electrical current may produce haz-
ardous situations. Touching live parts can result
in electrical shock, burns or death.
– Work on mains voltage must only be performed
by qualified, skilled personnel.
– National wiring regulations and electrical
operating conditions must be observed (e.g.
D: VDE 0100, A: ÖVE-ÖNORM E8001-1,
CH: SEV 1000).
– Only use genuine replacement parts.
– The floodlight enclosure heats up when the
light is on. Only align the LED panel once it has
cooled down.
– Repairs must be made by specialist workshops.
3. LS 150 M LED / LS 300 M LED
Proper use
LED floodlight suitable for wall mounting indoors
and outdoors.
Features
– Tilting and turning LED panel.
Models
– LS 150 M LED
– LS 300 M LED
Package contents (Fig. 3.1 / 3.2)
Floodlight adjustment range (Fig. 3.3 / 6.1)
Product dimensions for LS 150 M LED (Fig. 3.4)
Product dimensions for LS 300 M LED (Fig. 3.5)
Product components (Fig. 3.6)
A
LED panel
B
Enclosure
C
Wall mount
Technical specifications
– LS 150 M LED dimensions (H × W × D):
178 × 157 × 167 mm
– LS 300 M LED dimensions (H × W × D):
218 × 213 × 184 mm
– LS 150 M LED output:
22.6 W / 1760 lm / 77 lm/W
– LS 300 M LED output:
30.6 W / 3120 lm / 101 lm/W
– Power supply:
220 – 240 V, 50 / 60 Hz
– Colour temperature:
4000 K (neutral white)
– Life expectancy (L70 B10):
50000 hours
– Area illuminated to the front by LS 150 M LED:
– Area illuminated to the front by LS 300 M LED:
– Floodlight swivelling range:
horizontally ± 40°
vertically + 110° to -40°
– Recommended mounting height:
– Temperature range:
-10°C to +30°C
– IP rating:
– Protection class:

4. Electrical installation

Connection
The supply lead is a 2 or 3-core cable:
L = phase conductor (usually black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green / yellow)
Note:
The protective-earth conductor need not be
connected for this product.
Wiring diagram (Fig. 4.1)
The light source of this LED floodlight cannot be
replaced. If the light source needs to be replaced
(e.g. at the end of its service life), the complete LED
floodlight must be replaced.
– 10 –
5. Installation
Hazard from electrical power.
Touching live parts can result in electrical shock,
burns or death.
• Switch OFF power and interrupt power supply.
• Using a voltage tester, check to make sure the
light is disconnected from the power supply.
• Make sure power supply remains interrupted.
Risk of damage to property!
Mixing up connection leads may produce a short
circuit.
• Identify connection leads.
• Re-connect connection leads.
Preparing for installation
• Check all components for damage.
Do not use the product if it is damaged.
240 cm²
• Select an appropriate site to install the product.
– Vibration-free.
355 cm²
– Not in explosive atmospheres.
– Not on normally flammable surfaces.
– Do not look into the LED light from a short
distance (<20 cm).
1.8 - 2 m
– Installing LED floodlight in horizontal
position (± 15°).
IP 44
• Correctly aiming LED floodlight. (Fig. 5.1)
I
Mounting procedure
• Check to make sure the power supply is
switched OFF. (Fig. 4.1)
• Unscrew retaining screw. (Fig. 5.2)
• Detach enclosure from wall mount. (Fig. 5.2)
• Detach plug-in terminal from wall mount.
(Fig. 5.3)
• Mark drill holes. (Fig. 5.4 / 5.5)
• Drill holes and fit ground plugs. (Fig. 5.6 / 5.7)
• Pierce web. Fit sealing plug, feed cable through
(concealed power supply lead). (Fig. 5.8 / 5.9)
• Break off one of the two lugs.
Pierce web.
Feel through cable (surface-mounted power
supply lead).
(Fig. 5.10 / 5.11)
• Connect conductors. (Fig. 5.12 / 5.13)
• Connect plug-in terminal. (Fig. 5.12 / 5.13)
• Fit enclosure onto wall mount. (Fig. 5.14)
• Screw in locking screw. (Fig. 5.15)
• Switch ON power supply. (Fig. 5.15)
6. Cleaning and Maintenance
Hazard from electrical power.
Contact between water and live parts can result in
electrical shock, burns or death.
• Only clean tool in a dry state.
Risk of damage to property!
Using the wrong detergent can damage the light.
• Clean unit with a moist cloth without detergent.

7. Troubleshooting

Unit without power.
– Fuse not switched ON or faulty.
• Switch ON fuse.
• Change faulty fuse.
– Break in wiring.
• Switch ON mains switch.
• Check wiring with voltage tester.
– Short circuit in mains power supply lead.
• Check connections.
Unit does not switch ON.
– Mains switch OFF.
• Switch ON mains switch.
– Fuse not switched ON or faulty.
• Switch ON fuse.
• Change faulty fuse.
– Light source faulty.
• The light source cannot be changed.
Completely replace unit.
8. Disposal
Electrical and electronic equipment, accessories
and packaging must be recycled in an environmen-
tally compatible manner.
Do not dispose of electrical and electronic
equipment as domestic waste.
EU countries only:
Under the current European Directive on Waste
Electrical and Electronic Equipment and its imple-
mentation in national law, electrical and electronic
equipment no longer suitable for use must be
collected separately and recycled in an environ-
mentally compatible manner.
– 11 –
GB

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ls 300 m led

Inhaltsverzeichnis