Connect the Ethernet Cable
1. Connect the Ethernet cable's M12 connector to the vision sensor's Ethernet
connector.
2. Connect the Ethernet cable's RJ-45 connector to a switch/router or PC, as
applicable.
Connect the Breakout Cable
Note: Unused wires can be clipped short or tied back using a tie made of non-
conductive material. Keep all bare wires separated from the +24VDC wire.
1. Verify that the 24VDC power supply being used is unplugged and not
receiving power.
2. Optionally, connect the I/O or serial wires to an appropriate device (for
example, a PLC or a serial device).
3. Attach the Breakout cable's +24VDC (Red wire) and GROUND (Black wire)
to the corresponding terminals on the power supply.
CAUTION:
observe the polarity shown.
4. Attach the Breakout cable's M12 connector to vision sensor's Power, I/O
and RS-232 connector.
5. Restore power to the 24VDC power supply and turn it on if necessary.
Never connect voltages other than 24VDC. Always