emergency. Read the information on the rating label and the connection
diagram before connecting the appliance to the mains.
 When the socket is not accessible for the user or a fixed electrical connection
of the appliance is required, an all-pole disconnecting device must be
incorporated during installation. Disconnecting devices are switches with a
contact opening distance of at least 3 mm. These include LS-switches, fuses and
protectors (EN 30335).
Move a screwdriver (1) slightly downwards (2) to open the box.
Connection diagram
Voltage heating elements 230V.
Any kind of connection: the safety
wire must be connected to the
terminal.
1 For 230 V earthed one-phase
connection, bridges connect 1-2-
3 terminals and 4-5 terminals
Protective ground to
PE
32
Recommended
type of
connection lead.
H05VV-F3G4