Multiple error signals are indicated with a pause of 2 seconds between one signal and the next. The er-
ror signals persist until a complete automation manoeuvre is performed (opening and closing).
If an obstacle is detected while closing, the control unit reverses the movement and switches to slow
mode as it searches for the closing travel limit. To reset the automation must complete the opening
cycle, if not, every time the safety device is activated the automation will search for the travel limit.
If the obstacle is detected during a timed opening, a manual command via remote control (CH1) or but-
tons, O/C or ENTER is required to restart the automation.
BATTERY CHARGE CARD (BUILT-IN)
If the battery is connected, the automation will be operative also in the event of a power failure. If volt-
age falls below 11.3 Vdc, the automation stops operating (the control panel remains powered); if it falls
below 10.2 Vdc, the card disconnects the battery completely (the control panel is no longer powered).
OBSTACLE DETECTION
The obstacle detection function (settable via the trimmer FR), if activated during the opening phase, re-
closes the door by approx. 20 cm, and during closing activates a complete opening cycle.
IMPORTANT: the control panel logic may interpret mechanical friction as an obstacle.
N.B. the O/C button on the card has the same function as the OPEN/CLOSE key.

9. ADVANCED FUNCTIONS

Clock function: a timer may be used (e.g. weekly), connected to the input of the open-close button, to keep
the door open in set time intervals, to then enable automatic re-closure.
N.B. the door remains open while the Op/Cl input is engaged.
Open only" function: by setting dipswitch 1 to ON and dipswitch 4 to OFF, the Op/Cl input will only operate
as an opening command, while the door will close exclusively after the set interval for automatic closure.
10. BUILT-IN 433.92 MHZ RADIO RECEIVER
The radio receiver can learn up to max. 30 codes in rolling codes (BUG2R, BUG4R, K-SLIM-RP, T-4RP) set
as required.
RADIO CONTROL LEARNING
1_ briefly press the key RADIO to associate a radio control with the function OPEN/CLOSE;
2_ led DL3 turns off to indicate code learning mode (if no code is entered within 10 seconds, the card
exits programming mode);
3_ press the key of the radio control to be used;
4_ led DL3 turns on again to confirm memorisation (if this does not occur, wait 10 seconds and repeat
the steps from point 1);
5_ to memorise other radio controls, repeat the procedure from point 1, for up to a maximum of 30
transmitters.
6_ to exit learning mode without memorising a code, briefly press the key RADIO.
N.B.:
if the maximum number of radio controls is reached (30), led DL3 flashes quickly for ap-
prox. 3 seconds, without performing memorisation.
REMOTE PROGRAMMING VIA T-4RP, K-SLIM-RP and BUG-R
It is also possible to learn the new versions of the radio controls T-4RP, K-SLIM-RP and BUG-R remotely,
i.e. without acting directly on the receiver programming keys.
A radio control previously programmed on the receiver is all that is needed to open the remote pro-
gramming procedure for new radio controls, programmed via TAUPROG.
Activation of self-learning mode of the control unit and memorisation of the new radio control.
This operation enables memorisation of the new radio control code on the control unit, but an operational
"RP" radio control must already be available. The subsequent operations must be performed in the vicinity