Herunterladen Inhalt Inhalt Diese Seite drucken

Dip-Switches - tau K691M Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
Turning clockwise increases the motor's operating force.
BJ
Trimmer that regulates the loosening of the belt/chain from the track at the end of the clo-
sing operation (available from version 5v12)

7. DIP-SWITCHES

1
on: at the end of opening, the door closes automatically after a time interval set on the trimmer
A.C.T.;
off: closure requires a manual command;
2
on: with the automation running, a sequence of open/close commands activates a door sequence
OPEN-CLOSE-OPEN-CLOSE, etc. (see also dip switch 4);
off: in the same conditions, a sequence of open/close commands activates a door sequence OPEN-
STOP-CLOSE-STOP-OPEN-STOP, etc. (step-step function);
3
on: slowdowns both during opening and closing operations are reduced by 30% (they start after the
factory settings' ones)
off: factory settings' slowdowns both during opening and closing operations
When changing the position of Dip-switch n°3, you must carry out the stroke setup
procedure through ENTER of PROG buttons.
4
on: NO-REVERSE function active; the door ignores the closing commands during opening and inverts
the direction of door travel only in the closing phase;
off: on activation of the open-close button, the direction of travel is inverted also in the opening phase;
5
on: the pre-flashing function is enabled;
off: the pre-flashing function is disabled;
6
on: the "photocell check" function is enabled;
off: the "photocell check" function is disabled. N.B. to be used when photocells are not used;
8. FEATURES OF K691M
LED - DL3
As well as indicating the presence of power, this led indicates any errors by means of a set series of
flashing signals:
Continuous flashing: storage in progress or setup not completed;
always lit:
1 flash:
Check the mains voltage, charge the battery, replace the battery;
2 flashes:
Disable fototest (dipswitch 6 set to OFF), check photocell operation and relative connection;
3 flashes:
check thermal magnetic cut-out (upline of system), check fuses;
4 flashes:
Peak of excessive motor absorption, ensure absence of obstacles along door travel, check motor absorp-
tion under no load and applied on the door;
5 flashes:
check wiring, check encoder, check that the motor rotates freely when powered directly by battery, check
fuse F1;
6 flashes:
Ensure absence of obstacles along door travel and smooth movement of the door;
7 flashes:
Perform memorisation procedure.
8 flashes:
check wiring, check that the motor rotates freely when powered directly by battery, check fuse F1;
normal operation;
backup battery voltage less than 11.3 Vdc;
fototest error;
mains power failure;
max. current limit exceeded;
no encoder signal;
presence of obstacle;
no memorisation procedure performed;
no motor signal;