safe handling and control of the power tool in unexpected situations.
5) Service
This will ensure that the safety of the power tool
is maintained.
Safety instructions for electric soldering tongs
WARNING
Read all safety warnings and all instructions. Failure to follow the warnings and
Save all warnings and instructions for future reference.
Only connect the power tool to an outlet with protected earth. There is a
risk of electric shock.
of approx. 800°C. Touching these parts can cause severe burns.
that are still hot during the cooling phase can cause severe burns. The power
tool takes a long time to cool down after unplugging.
liquid. There is a danger of injury from electric shock and/or sudden spurting of
the liquid. This could damage the power tool.
the hot power tool.
point or wear suitable protective gloves during soldering.
and pipe get very hot and can cause severe burns. The soldering point stays
very hot for a long time after completion.
tions. Touching the hot parts causes severe burns.
responsible person. Otherwise there is a risk of operating errors and injuries.
Only allow trained persons to use the power tool. Apprentices may only use
the power tool when they are over 16, when this is necessary for their training
and when they are supervised by a trained operative.
REMS customer service workshop in case of damage.
cable cross-section and at least with the protection class approved in 1.4.
Electrical data. Use extension leads up to a length of 10 m with cable cross-sec-
tion 1.5 mm², from 10 – 30 m with cable cross-section 2.5 mm².
WARNING
Danger with a medium degree of risk which could result in
death or severe injury (irreversible) if not heeded.
CAUTION
Danger with a low degree of risk which could result in minor
injury (reversible) if not heeded.
NOTICE
Material damage, no safety note! No danger of injury.
Read the operating manual before starting
Use eye protection
Use hand protection
Power tool complies with protec ion class I
Environmentally friendly disposal
CE conformity mark
1. Technical Data
Use for the intended purpose
WARNING
Only use the power tool the intended purpose of soft soldering of copper pipes.
All other uses are not for the intended purpose and are therefore prohibited.
1.1. Scope of Supply
Electric soldering tongs, solder, paste, cleaning brush, instruction manual,
Slippery handles prevent
Touching parts
Placing the hot power tool on a
-
There is a danger of accident.
REMS Hot Dog 2 in steel case
REMS Solder Cu 3
REMS Paste Cu 3
Steel case REMS Hot Dog 2
REMS CleanM
1.3. Applications
1.4. Electrical data
Protection class
Protection class
Emission at workplace
1.6. Vibrations
Weighted effective value of acceleration
The indicated weighted effective value of acceleration has been measured
against standard test procedures and can be used by way of comparison with
another device. The indicated weighted effective value of acceleration can also
be used as a preliminary evaluation of the exposure.
CAUTION
The indicated weighted effective value of acceleration can differ during oper-
ation from the indicated value, dependent on the manner in which the device
is used. Dependent upon the actual conditions of use (periodic duty) it may be
necessary to establish safety precautions for the protection of he operator.
2. Preparations for use
2.1. Electrical connection
WARNING
Caution: Mains voltage present! Before connecting the electric soldering
tongs, check whether he voltage given on the rating plate corresponds to the
mains voltage. Only use outlets/extension leads with a functioning protective
contact.
On building sites, in a wet environment, indoors and outdoors or under similar
installation conditions, only operate he electric soldering tongs on the mains
with a fault current protected switch (FI breaker) which interrupts the power
supply as soon as the leakage current to earth exceeds 30 mA for 200 ms.
When using an extension lead, a cable cross section suitable for the power of
the electric soldering tongs must be chosen. The extension lead must be
2.2. Preparing the electric soldering tongs

3. Operation

Once connected to the mains, the soldering pistol is switched on. After
approximatively 5 min. it is ready for use. By pressing the handles (3) together,
the soldering pieces (1) open. The front holes of the soldering pieces are
provided for the diameters 10 to 16 mm, the rear holes for the diameters 18 to
28 mm. Position the soldering pieces (1) corresponding to diameter on the pipe
close to the sleeve or onto the sleeve so that there is a
between the soldering pieces (1) and the pipe (or sleeve) and that the solder
can be joined without touching the soldering pieces (1).
The soldering process needs 10 to 30 sec. depending on the diameter of pipe
and the melting temperature of the solder.
The soldering clamp is designed for continuous operation.
For soft solder
For the preparation of the solder point put REMS Paste Cu 3 onto the pipe.
that the required temperature for soldering is visible through the change of
any case however REMS Lot Cu 3 has to be added. REMS Lot Cu 3 and REMS
Paste Cu 3 have been specially developped for drinking water installations and
correspond to the respective DIN standards.

4. Maintenance

WARNING
plastic parts (e g. housing) only with REMS CleanM machine cleaner (Art. No.
140119) or a mild soap and a damp cloth. Do not use household cleaners These
often contain chemicals which can damage the plastic parts. Never use petrol,
g
163020
160200
160210
163350
140119
230 V, 50 – 60 Hz, 440 W
100 / 110 V, 50 – 60 Hz, 440 W
IP 20
1
70 dB(A)
2.5 m/s²