Herunterladen Diese Seite drucken

HANSGROHE Variarc 14870-Serie Montageanleitung Seite 21

Vorschau ausblenden Andere Handbücher für Variarc 14870-Serie:

Werbung

Important! The fitting must be installed, flushed
and tested after the valid norms!
Assembly
1.
Flush through the supply pipes.
2.
Place the mixer including the sealing washer
in position on the sink.
3.
Slip the plastic washer, the slide washer, the
metall washer and collar over the hoses and
threaded base and tighten the collar nut by
hand. If there is not enough space, please use
only the slide washer and the metal washer
without the plastic washer.
4.
Tighten screws.
5.
Connect the connecting hose / supply pipes to
the isolation valves; cold right - hot left.
The hot and cold supplies must be of equal
pressures.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
( 1 MPa = 10bar = 147 PSI )
Hot water temperature:
Recommended hot water temp.:
Rate of flow:
Test certificate
DVGW
14870XXX
14875000
14878000
English
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80° C
65° C
P-IX
SVGW
P-IX
X
9481/IA
P-IX
9481/IA
Hansgrohe single lever mixers can be used
together with hydraulically and thermically
controlled continuous flow heaters if the flow
pressure is at least 0,15MPa.
To adjust the hot water limiter on single lever
mixers, please see page 6.
No adjustment is necessary when using a
continuous flow water heater.
Spare parts (see page 4)
1
handle
1
screw cover
2
flange
3
nut
4
cartridge cpl.
5
aerator cpl.
6
fixing set
7
connection hose 900 mm
8
spout cpl.
9
sealing set
10
ELASTOP stop unit
XXX = Colors
000 chrome plated
750 alux
800 stainless steel optic
ACS
NF
WRAS
X
X
10490XXX
96338000
96468000
96461000
92730000
13913000
95049000
94082000
92830XXX
92646000
94849000
KIWA
DK
PZH/HK/W
X
5

Werbung

loading

Diese Anleitung auch für:

Variarc 14878000Variarc 14875-serie