1. TECHNICAL DATA

Power supply
Absorption
Motor power
Geared motor torque
Jogging
Accessories output
Degree of protection
Weight
Wing dimension
mm = Door width
kg = Door wing weight
Recommended
dimensions
Limit
dimensions

2. REFERENCE TO ILLUSTRATIONS

2.1 Standard installation references (fig. 1)
ATTENTION: Only use DITEC's safety devices and accessories for installation.
1 Geared motor
2 Radar
3 Plug in to mains
4 Sliding arm
2.2 Geared motor references (fig. 2 and 3)
5 Electrical board
6 Control cable plug
7 ON/OFF switch
8 Motor faston
9 Encoder connector

3. INSTALLATION

3.1 Preliminary checks
Check for wing stability and weight, and make sure that door movement is smooth and friction-free (strengthen
frame if necessary). If door closure systems are installed, these must be removed or completely disactivated.
Warning: when installing doors that divide rooms having different pressures, check for their working efficiency.
3.2 Selecting the appropriate arm
Use the articulated arm for doors opening outwards as seen from the actuator side (fig. 4).
Use the sliding arm for doors opening inwards as seen from the actuator side (fig. 9).
3.3 Installing the geared motor with articulated arm
1.
Remove the housing and mount the actuator on to the wall according to the measurements shown in
figs. 3, 5, 6 or 7 and with reference to the hinge centre line.
2.
Correctly mount the articulated arm, taking care not to tighten at this stage the screws A ,and secure it to
the actuator making sure that it properly fits into the arms support seat (fig. 5 and 8).
3.
Secure bracket B to the door (fig. 6 or 7 and 8).
4.
Close the door and adjust the arm (fig. 8). Next, tighten screws A .
Note: Use the door stop provided for maximum door opening.
3.4 Installing the geared motor with sliding arm
1. Remove the housing and mount the actuator on to the wall according to the measurements shown in
figs. 3, 10, 11 or 12and with reference to the hinge centre line.
2. Drill holes into guide C and secure the guide to the door (fig. 10 and 13).
3. Introduce the sliding arm shoe D into the guide (fig. 13). Secure the arm to the actuator, making sure that
it properly fits into the arm support seat.
4. Fit the cover and the two endpieces on to guide C (check for proper mounting direction) (fig. 10 and 13).
Note: Use the door stop provided for maximum door opening.
DITEC S.P.A - IP1546 15/09/1999 - SPRINT
Sprint
230 V~ 50 Hz
0.2 A
S2=30min,S3=80%
24 V
/ 0.15 A (nominale) / 0.3 A (picco)
mm 2000
1200
1000
10 Control terminal board
11 Housing
12 Arms support
13 Base plate
12
Sprint J
120 V~ 60 Hz
0.4 A
15 W
25 Nm
IP12D
5 kg
80
100 150
200
250
kg