Herunterladen Inhalt Inhalt Diese Seite drucken

Rack Installation; Connections; Connection With The Mains; Cleaning And Maintenance - EuroLite SBM-16 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für SBM-16:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Procedure:
The installation should be attached outside areas where persons may walk by or be seated.

5.1 Rack installation

This 19" distributor 16 A is built for 19" racks / steel cabinets (483 mm). The rack you use should be a
double-door-rack where you can open the frontpanel and the rear panel. The rack should be provided with a
cooling fan. When mounting the 19" distributor into the rack, please make sure that there is enough space
around the device so that the heated air can be passed on. Steady overheating will damage your device.
You can fix the 19" distributor with four M6 screws in the rack.
Be careful when mounting the 19" distributor into the rack. Put the heaviest devices into the lower part of the
rack.

5.2 Connections

5.2.1 Connection with the mains

Connect the device to the mains with the CEKON plug.
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
5.2.2 Outputs
Output is via six safety sockets and one 16 A three-phase-current output socket.
Connect your loads via the output-sockets. The maximum load per channel is 3,680 W (resistive) and
22080 W respectively. Please note that the maximum current must never be exceeded.
Before taking into operation for the first time, the installation has to be approved by an expert!

6. CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
DANGER TO LIFE!
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
13/14
00043364.DOC, Version 2.0