Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Gas Connection - Candy TRIO 9501 Gebrauchs- Und Installationsanweisungen

Vorschau ausblenden Andere Handbücher für TRIO 9501:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 54
Installing a domestic appliance can be a complicated operation which if not carried out correctly, can seriously affect
consumer safety.
It is for this reason that a professionally qualified person should undertake the task who will carry it out in accordance
with the technical regulations in force.
In the event that this advice is ignored and the installation is carried out by an unqualified person, the manufacturer declines
all responsibility for any technical failure of the product whether or not it results in damage to goods or injury to individuals.
• Before installing the appliance, the technician must :
- Check the compatibility between the Trio and the gas installation.
The Trio is factory set for use with the gas type as stated on the packaging and repeated on the rating plate affixed to the cooker.
Natural gas G 20-20 mbar / G 25-25 mbar : main gas
- If necessary, change the gas.
To adapt the gas burners cooker fit suitable jets that provide the nominal flow rate go to page 3.
• For installation the technician must :
The Trio is Class2 - Sub class 1 ; furniture adjacent to the unit must not be higher than the top of the appliance.
- The cooker has adjustable feet for perfect levelling on the floor.
- Make the gas connection to the installation according to the gas supply.
- Connect the cooker electrically in compliance with the information given on page 4.
- If the gas type has been changed, adjust the minimum flow of each gas burner on page 3.
- Connect the Trio to the water supply and the water drainage (page 5).
ANY MODIFICATION MADE TO THE GAS SETTING SHOULD BE NOTED ON THE RATING PLATE AFFIXED TO THE COOKER.

• GAS CONNECTION

This must be done in compliance with the regulations in force in the installation country. In all cases, on the gas feed pipe provide a
stopcock, a regulator or regulator release device for propane gas. Only use valves, regulators ends and flexible tubes, regulators with
the official mark of the installation country.
Gas connection according to installation :
Natural Rigid, Flexible hose with mechanical fittings (1) - Soft rubber tube (2)
Butane Rigid, Flexible hose with mechanical fittings (1) - Soft rubber tube (2)
Propane Rigid, Flexible hose with mechanical fittings (1) - Soft rubber tube (2)
1 - provided the flexible hose can be inspected for its entire length.
2 - provided the soft rubber tube can be inspected for its entire length, its length does not exceed 1.5 metres and it is fitted with suitable
clamps at the ends.
1, 2 - soft tubes and flexible hoses with mechancial fittings must be arrange to be away from any flames, and not deteriorated by the
combustion gases, hot cooker parts or by any spills of hot food.
• THREE CONNECTION OPTIONS :
• RIGID PIPE CONNECTION
Connect directly to the manifold fittings.
• CONNECTION BY FLEXIBLE HOSE WITH MECHANICAL FITTINGS
We recommend this type of connection.
Screw the hose nuts directly onto the manifold fitting on the one hand and onto the stop cock of the piping on the other hand.
• CONNECTION BY SOFT RUBBER
We do not recommend this type of connection.
To be reserved solely for old installations not enabling any other option.
Screw the compliant end piece (2)
Fit the soft tube to the end piece on
the one hand and to the regulator or
to the valve outlet on the other hand.
(2) In all cases, make sure the seal is fitted. Following the connection operations, test the leak tightness using soapy water, testing by
flame is strictly prohibited.

INSTALLATION

GAS MODEL
2 GB

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Trio 9503

Inhaltsverzeichnis