Position Symbol
Explanation
15
Setting the day and time
The LED above this symbol flashes if
the day and time are being set
( Chapter 4.4, page 60).
16
7d week program
The LED above this symbol flashes if
the 7d week program is being set
( Chapter 4.5.6, page 63).
14
Day program P6
The LED above this symbol flashes if
the day program P6 is being set
( Chapter 4.5.5, page 63).
5
Open-window detection
This function detects when a window in
the room is open due an accompanying
sudden drop in temperature.
6
Adjust
Settings can be made via this symbol.
12
Heating
The appliance is heating when the LED
next to this symbol lights up.
7/8
Operating mode/Confirm/On
Press this key to select the operating
mode or confirm a setting. Press this
key to switch the appliance on when
the appliance is switched off.
11/10/9
Up/Down/Keylock
Press these keys to reduce or increase
a value
(e.g. the temperature). The keylock
can be activated via both keys to
prevent the settings being changed
accidentally.
13
Display output
Table 55 Displays (
Fig. 2, page 211)
Heat Convector 4000 – 6720883017 (2020/11)

4.5.1 Calling up and setting operating modes

To call up one of the operating modes:
▶ Press the
key repeatedly until the indicator light below
the pictogram of the required operating mode lights up.
The last temperature set in this operating mode appears on
the display.
To change the temperature of the operating mode:
▶ Press the
or
key until the required temperature is
set.
The set temperature is saved automatically if the key is not
pressed for 5 seconds.
The room temperature appears on the display.

4.5.2 Heating mode operation mode

The control unit keeps the convector at the set temperature.
The temperature can be set from 7 °C and 12 °C up to 28 °C.
The default setting is 19 °C.
To call up and set the heating mode operating mode:
▶ Proceed as described in Chapter 4.5.1, page 61.
If the temperature for the heating mode operating mode is
lower than the ECO operating mode temperature, the
temperature setting for the ECO operating mode is
automatically reduced to 1 °C below the temperature of the
heating mode operating mode.

4.5.3 Operating mode ECO

The temperature default setting for the ECO operating mode is
3 °C below the temperature of the heating mode operating
mode.
The temperature can be set from 6 °C to 1 °C below the
temperature of the current operating mode.
To call up and set the ECO operating mode:
▶ Proceed as described in Chapter 4.5.1, page 61.
We recommend setting the ECO operating mode during the
night or if the room is not going to be used for more than
2 hours.
Operation