NOTE:
The RJ45 connector of the patch cable used must be flat enough to enable
the parts of the coupler to be assembled. Narda recommends an outdoor
Cat 7 patch cable with a maximum length of 100 m.
Fig. 8:
1
End nut
2
Sealing ring (to be cut on one side before assembly)
3
Seal body
4
RJ45 connector
5
Sheathing
6
Coupler
6a
Ridge
1. First slide the end nut (1) and then the seal body (3) over the RJ45
connector (4) onto the patch cable.
2. Cut the sealing ring (2) on one side and mount it onto the patch cable
between (1) and (3).
3. Carefully slide the flexible grips of the seal body (3) over the sealing ring
(2).
Slide the seal body over the sealing ring until the sealing ring is fully en-
closed by the grips.
66
1
3
2
RJ45 coupler design
SignalShark 3330 Outdoor Unit
5
4
6
6a
Narda