When the device is in cooling or dehumidifying mode, the ambient temperature sensor
senses the evaporator coil temperature. When this temperature is below -1°C, the
compressor stops operating. Approximately 10 minutes later, or when the coil temperature
is ≥ 7°C, the device starts to cool again.
Overload protection
In the event of a power loss or cut, there is a 3-minute delay until the compressor restarts.
Self-evaporating system
The self-evaporating system uses the collected water to cool the condenser coils for a
more efficient performance. There is no need to empty the water tank in cooling operation.
The condensated water is evacuated via the air exhaust
and its connected exhaust hose
6
.
A
The device requires ventilation to the outside, so that the (hot) exhaust air and moisture
can be dispelled outside the room that is being cooled.
The evaporation in the device needs to be well dried out when storing the device.
• Switch off the device
• Remove the plug from the water tank outlet
8
• Place the drain hose over the water tank outlet
• Make sure the drain hose is not kinked and clear of any obstructions
• Place the drain hose in a bucket or drain and make sure the water can flow out
• When all water has been drained, remove the drain hose and place the plug back in the
water tank hole.
Continuous drain hose
Remove the rubber sealing plug
(Inner diameter=16mm)
Drainage
For continuous or unattended operation, connect the drain hose
E
outlet of the device.
to the drain opening
7
In this way condensate water can flow into a bucket or drain (by
gravity).
7
• Switch off the device
• Remove the drain plug from the drain outlet
7
• Store the plug safely
• Place the drain hose over the drain outlet
• Make sure the drain hose is not kinked and clear of any
obstructions
• Place the drain hose in a bucket or drain and make sure the water
can flow out
• Do not submerge the hose end into water, otherwise it can cause
an "Air lock" in the drain hose