8

Maintenance, cleaning and repair

EN
8.1

Maintenance

Maintenance should only be carried out by a qualified elec-
trician and must be in accordance with local regulations,
standards and requirements.
8.2

Cleaning

Only clean the Ford Connected Wall Box with a dry cloth.
Never use aggressive cleaning agents, solvents, fuel or wax.
DANGER
High voltages.
Danger of fatal electric shock. Never clean the wall box
with a high-pressure cleaner or similar device.
8.3

Repair

Unauthorised repair of the Ford Connected Wall Box is not
permitted. In case of failure, the entire unit must be re-
placed. Ford Motor Company Limited (Ford) reserves the ex-
clusive right to perform repairs to the wall box . The only ser-
viceable components are the design cover and the charging
cable. The charging cable must be replaced by a qualified
electrician. The only serviceable components are the design
cover and the charging cable. The charging cable must be re-
placed by a qualified electrician.
NOTE
The charging cable can be replaced a maximum of four
times over the lifetime of the wall box.
8.4

Disposal

Dispose of packaging in the appropriate recycling container
in accordance with national regulations.
The symbol of the crossed-out waste bin indicates
that this electrical/electronic device must not be dis-
posed of in household waste at the end of its service
life. Dispose of the device free of charge at a local col-
lection point for electrical/electronic devices. Ad-
dresses can be obtained from your city or local author-
ity. Separate collection of electrical and electronic
devices enables re-use, material recycling or other
forms of re-utilization of waste equipment while also
10
avoiding the negative effects of hazardous substances
which may be contained in the devices on the environ-
ment and on human health.

Declaration of Conformity

9
Ford Motor Company Limited (Ford) hereby declares that
the radio equipment type "Ford Connected Wall Box" con-
forms to directive 2014/53/EU.
The Ford Connected Wall Box also conforms to the follow-
ing standards and regulations:
– 2014/53/EU (Radio Equipment Directive) [OJ L 153,
22.5.2014, p. 62-106]
– 2011/65/EU (RoHS-Directive) [OJ L 174, 1.7.2011, p.
88-110]
– [2014/53/EU - Artikel 3 (1) a) Sicherheit]
– EN IEC 61851-1:2019; EN 61439-1:2011; IEC 61439-7:2018,
IEC 62955:2018 (RDC-MD),
– EN 62233:2008
– [2014/53/EU - Artikel 3 (1) a) Sicherheit (Funkteil)]
– EN 62368-1:2014; EN 62311:2008
– [2014/53/EU - Artikel 3 (1) b) EMV]
– EN 61000-6-2:2005; EN 61000-6-3:2007 + A1:2011; IEC
61851-21-2:2018
– [2014/53/EU - Artikel 3 (1) b) EMV (Funkteil)]
– EN 301 489-1 V2.2.3 (2019-11); EN 301 489-17 V3.2.4
(2020-09)
– [2014/53/EU - Artikel 3 (2) Funkspektrum]
– EN 300 328 V2.2.2 (2019-07); EN 301 893 V2.1.1
(2017-05)
– [2011/65/EU]
– EN IEC 63000:2018
The Ford Connected Wall Box was developed, manufac-
tured, tested and supplied in accordance with the above-
mentioned standards and regulations, and in accordance
with the relevant standards for safety, electromagnetic
compatibility (EMC), and environmental compatibility. The
full text of the EU declaration of conformity is available at
the following internet address: https://owner.ford.com
SKLJ98-10C823-AA

Installation checklist

10
Please complete the Ford Connected Wall Box Installation
Checklist
Variant:
1-phase
3-phase
Serial number:
Material number:
General preconditions:
Installation, electrical connection, and initial opera-
tion of the wall box has been carried out by a quali-
fied electrician.
The wall box has been inspected for visual damage
before installation and use.
Local installation conditions:
The wall box has not been installed in an explosion
sensitive area (Ex Zone).
To achieve optimal performance of the wall box
areas with direct sunlight have been avoided.
The wall box has been installed in a location where
falling objects cannot damage the wall box.
The location of the wall box has been selected in
such a way that vehicles cannot inadvertently collide
with it.
The legal requirements for electrical installations,
fire protection, safety regulations and escape routes
have been met.
The use of the correct residual current circuit breaker
(RDB) and the correct residual current device (RCD)
have been ensured.
The charging cable does not obstruct any passage-
ways.
Ford Connected Wall Box Installation Manual