TECHNICAL CHARACTERISTICS 
 
Frequency 
Coding 
Memory 
Number of relays 
Supply 
Relay contacts 
Standby/Op. consumption 
Op. temperature 
Watertightness 
Size 
Box dimensions 
 
INSTALLATION AND CONNECTIONS  
Attach  the  rear  part  of  the  housing  to  the  wall  using  the  plugs  and  screws  supplied.  Pass  the 
cables through the bottom of the receiver. Connect the power cables to the terminals marked in 
the mother board, as indicated. Fix the receiver front to the rear part using the screws supplied. 
 
OPERATING 
The  pilot  lights  are  activated  every  5  seconds  to  indicate  the  correct  supply  of  power  to  the 
equipment. Upon receiving a code, the receiver checks whether it is in its memory, activating the 
corresponding  relay.  The  relay  activation  mode  is  selected  in  either  impulse  (monostable)  or 
ON/OFF using the Imp/Bies jumper (only with the relay 2). 
For adjustment of relay 1, see manual of the programming tool. 
 
PROGRAMMING 
Manual programming 
 
 
Press  the  receiver  programming  button  for  1  sec.  and  an  acoustic  signal  will  be  heard.  The 
receiver will enter programming (see table). If the receiver programming button is held pressed 
down, the receiver will pass cyclically from one configuration to the next. Once the programming 
configuration  for  the  transmitter  to  be  registered  has  been  chosen,  send  the  code  to  be 
programmed  by  pressing  the  transmitter.  Every  time  a  transmitter  is  programmed,  the  receiver 
will issue an acoustic signal for 0.5 sec.  
 
EN 
 
BASIC‐2B 
868,35MHz 
High security rolling code 
500 codes 
2 relays 
12/24Vac/dc ±10% 
1A 
60mA / 90mA 
‐20ºC to +85ºC 
IP54 (with glands IP65) 
63x74x25mm 
82x190x40mm 
 
3200683
 

Werbung