4.2 Outlet side
On the outlet side there is a diaphragm expansion vessel as
well as a pressure sensor and a pressure gauge.
2
Fig. 3 CBU146Outlet side
4.3 Indicator LED
LED, green for normal function, yellow for warning, red for
alarm and description text in the display.
4.4 Mode of operation
The pump is switched on based on pressure, and off based
on quantity, by a fully-automatic control unit. If a pre-set
pressure setting is exceeded, the pump switches on and the
frequency converter regulates the compact buster unit to the
set value, so that a constant pressure is always available. The
speed decreases as consumption reduces and the compact
booster unit switches off after a set minimum run time (0 to
600 seconds, default set to 60 seconds).
5

Technical Data

Separation of systems as a means to protect potable water
from being contaminated by fluids of the category 5 according
to EN 1717.
Media
Pump Medium:
Flow rate:
Pumping head:
Pressure values
Nominal pressure p:
Inlet pressure:
Operating temperatures
Medium temperature:
Ambient temperature
Specifications
Supply voltage:
1
Diaphragm
expansion vessel
2
Pressure sensor
3
Pressure guage
1
3
Non-portable water
Without aggressive, abrasive
and solid components
see Chapter Dimensions
Adjustable within the range of
pump characteristics, preset
to 60 m see chapter
Dimensions
PN 16
1.5 - 8 bar (depending upon
the model)
up to 30 °C
up to 40 °C
3/PE, AC 400 V, 50 Hz