Paragraph 14 – Password
Programming
P R O G
-
-
P a ss w o rd
* * **
P a ss w o rd
0 0 0 0
-
Paragraph 15 – Flow Alarm
Programming
Configuration
Alarm
Alarm Flow
Off
Flow
Off
Paragraph 16 – Level Alarm
Programming
PROG
-
-
Alarms
Level
Stop
-
EM00136424
-
+
Alarm Flow
Alarm Flow - On
On
Signals
Alarm Flow - On
Time
0 s
Alarm
Flow
Off
Recovery
Alarm Flow
Recovery
Signals
10
Alarm
Flow
Off
Alarm Level
Stop
-
Alarm Flow
Alarm
ESC
Alarms
Level
Alarm
-
rev. 1.0
By entering the password, you can enter the programming
menu and see all the set values. The password will be
requested whenever you seek to modify them.
The flashing line indicates the number than can be modified.
Use the
key to select the number (from 1 to 9), and the
key to select the number to be modified. Confirm by
pressing the
key. By setting "0000" (default), the
password is eliminated.
This makes it possible to activate (deactivate) the flow
sensor.
Once activated (On), press
number of signals the pump waits before entering alarm
mode (Setting Time = 0 s in the next menu) or priming mode
(Setting a Time other than 0 s in the next menu). When
is pressed, the number flashes. Use
value. Press
to confirm. Press
main menu.
In the Time menu, you can set the time for which the pump,
not having received the flow signal for the set number of
signals, enters priming mode before entering alarm mode. If,
during the priming time, the pump receives the flow signal
again, it will return to normal operation. If time = 0 s, after the
number of signals set, the pump will enter alarm mode
immediately, without performing priming. To edit and set the
time: when
is pressed, the number flashes. Then press
to set the value. Press
to go back to the main menu.
Batch mode can only be enabled in Recovery mode. The
pump repeats the number of strokes that were not detected
by the flow sensor. Press the
maximum number of signals that the pump can recover
before going into an alarm state. Pressing
the number to flash. At this point the user can use the
and
buttons to set the desired value. Press the
button to confirm. Press
This makes it possible to set the pump when the level
sensor alarm is activated. In other words you can decide
whether to stop dosage (Stop) or simply activate the alarm
signal without stopping dosage.
Changes can be made by pressing the
the
keys to set the alarm type. Confirm by pressing
the
key. Press
EN
Operation
Operation
to access the request for the
to go back to the
to confirm. Press
button to request the
to return to the main menu.
Operation
key, then using
to return to the main menu
to set the
will cause
11