Herunterladen Inhalt Inhalt Diese Seite drucken

voestalpine Böhler URANOS 1500 Bedienungsanleitung Seite 45

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 60
6
Hot start
Allows adjustment of the hot start value in MMA.
Permits an adjustable hot start in the arc striking phases,facilitating the start
operations.
Minimum 0%, Maximum 500%, Default std 80%, Default cls 150%.
Welding current
Allows the regulation of the welding current.
Minimum 3A, Maximum Imax, Default 100A, Default cls.
Arc force
Allows adjustment of the Arc force value in MMA.
Permits an adjustable energetic dynamic response in welding, facilitating the welder's
operations.
Increase the value of the Arc force to reduce the risk of electrode sticking.
Minimum 0%, Maximum 500%, Default std 30%, Default cls 350%.
Measurements selector
7
7-segment display
8
41
SYSTEM PRESENTATION
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis