Herunterladen Inhalt Inhalt Diese Seite drucken

Possible Faults, Causes And Solutions; Technical Data - Espa ACUAPLUS S Gebrauchsanweisung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
8. TROUBLESHOOTING
1)
The pump does not start.
2) The pump does not stop
3) The pump has no suction
4) The pressure or flow are insufficient
5) The motor overheats
6) The pump starts but stops in a short while (thermal protector)
7) The pump starts and stops constantly
8) The pump stops automatically
PROBLEM POSSIBLE PROBLEM
Pump blocked
1,5,6
3,4
Water entry filter obstructed
1,3,4
Total manometric height greater than foreseen
Incorrect voltage
1,5,6
3,4
Drop in the well water level
1
No electricity
Turbines worn down
4
5,6
Water temperature
1
Incorrect programming
Insufficient water detected
1
Insufficient water
1,3
2,4,7
Water loss through discharge line
1,8
Thermal protection error
1,8
Stop caused by level probes
1
Supply cable cut
Capacitor improperly connected
1,4
4
A gate valve closed
2,7
Water loss through installation tap
1
Water column is higher than the default pressure Revise the default pressure adjustment

9. TECHNICAL DATA

Liquid temperature: ......................... 4ºC - 40ºC
Ambient temperature: ..................... 0ºC - 40ºC
Storage temperature: ................... -10ºC - 50ºC
SOLUTIONS
Disassemble it and take it to an Official Technical
Service
Clean the filter
Check geometric height and load losses
Make sure the mains frequency and voltage
correspond to what
characteristics plate.
Make sure the suction remains submerged
Check fuses and other protection devices
Disassemble it and take it to an Official Technical
Service
Work with an appropriate temperature
Revise the programming
Reset the control and find out why there is
insufficient water
Wait for the water level to be restored and press
the reset button
Repair the leak
Reset the thermal protector or wait until it cools down
Wait until the well level is restored
Check electrical cable
Revise the connection according to the diagram
provided
Open the valve
Repair the leak
Ambient relative humidity, max.: ............... 95%
Motor class I.
Other data see Figure 7
12
EN
is indicated on the

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis