4.3 Front panel and controls
2 3
1
4 5
6
1 ON / OFF power button.
2 LED »Loop OK«. This green LED is displayed when the loop is in working condition.
3 LED «Protect / Clip M« error display. This red LED lights up when the driver unit for
the Master loop overloads, the input level for the Master loop is too high or the Master
loop is defective.
4 Power LED, ON / OFF display. This light indicates the device is on power.
5 LED »Protect / Clip S« error indicator. This red LED lights up when the driver unit for
the Slave loop overloads, the input level for the Slave loop is too high or the Slave loop
is faulty.
6 Input 1 setting (Line or microphone). This adjusts the signal level of INPUT 1.
7 Input 2 setting (Line or microphone). This adjuster is for the signal level of INPUT 2.
8 Input 3 setting (100V). This controls the level of INPUT3.
9 Metal Loss Compensation: Adjust to reduce interference with metal structures.
10 Input level indicator.
11 Master current output adjuster. Controls the electric current in the master loop.
12 Master loop output indicator.
13 Slave current output adjuster. Controls the electric current in the slave loop.
14 Slave loop output indicator.
15 6.35 mm headphone jack for monitoring.