Herunterladen Inhalt Inhalt Diese Seite drucken

Hama Touch Bedienungsanleitung Seite 5

Vorschau ausblenden Andere Handbücher für Touch:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
Warning – Batteries
• Avoid storing, charging or using the device in extreme
temperatures and extremely low atmospheric pressure (for
example, at high altitudes).
4. Getting Started
Note
Before use, ensure you insert the batteries in the measuring
station rst and then in the base station.
4.1 Insert batteries
Measuring station
• Open the battery compartment (23) and remove the contact
breaker.
• Then close the battery compartment cover.
Base station
• Remove the screen protector from the display.
• Open the battery compartment (17) and insert three AAA
Micro batteries with the correct polarity.
• Then close the battery compartment cover.
4.2 Replacing the batteries
Note – Replacing the batteries
• Note that the stations have to be resynchronised each
time after you change the batteries in the measuring or
base station.
• To do this, remove the batteries from the other station and
then reinsert them, or change them as required.
Measuring station
• Open the battery compartment (23), remove and properly
dispose of the depleted batteries, and insert two new AAA
Micro batteries with the correct polarity. Then close the
battery compartment cover.
Base station
• Open the battery compartment (17), remove and properly
dispose of the depleted batteries, and insert three new AAA
Micro batteries with the correct polarity. Then close the
battery compartment cover.
5. Installation
Note – Installation
• We recommend initially placing the base and measuring
stations in the intended locations without installing them
and making all the settings described in 6. Operation
– to do.
• Only install the stations once the appropriate settings
have been made and a stable wireless connection is
established.
Note
• The wireless transmission range between the measuring
and base stations is up to 30 m in open spaces.
• Before installation, ensure that wireless transmission
will not be disrupted by interference or obstacles like
buildings, trees, vehicles, high-voltage lines, etc.
• Before the nal installation, ensure that there is su cient
reception between the intended installation locations.
• When installing the measuring station, ensure that it is
protected from direct sunlight and rain.
• The international standard height for measuring air
temperature is 1.25 m (4 ft) above ground.
Warning
• Buy special or suitable installation material from a
specialised dealer for wall-mounting.
• Ensure that no faulty or damaged parts are installed.
• Never apply force during installation. This could damage
the product.
• Before installation, ensure that the chosen wall is suitable
for the weight to be mounted, and make sure that there
are no electrical wires, water, gas or other lines at the
installation site on the wall.
• Do not mount the product above locations where persons
might linger.
5.1. Base station
• Use the base to position the base station (19) on a level
surface.
• Alternatively, you can install the base station on a wall using
the opening (16) on the back.
5.2. Measuring station
• You can also position the measuring station on a level
outdoor surface.
• We recommend installing the measuring station securely on
an outdoor wall.
• Install an anchor, screw, nail, etc. in the wall of your choice.
• Hang up the base/measuring station using the opening (21)
intended for this purpose.
6. Operation
Note
Hold down the 'CH | ' button (12) or the 'MEM | ' button
(14) to select the values faster.
3

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

00186314

Inhaltsverzeichnis