power supply must only be operated in dry spaces.

Inappropriate use

Do not use with 6 volt batteries or
with non-rechargeable batteries!
The power supply must not be used to charge 6 volt lead batteries. If batteries
with a rated voltage of 6 volt are charged with the power supply, gas is created
immediately. Explosive oxyhydrogen gas is generated.
The power supply must not be used to charge non-rechargeable batteries and/or
nickel-cadmium batteries.
When charging these battery types with the power supply, the outer cover may
rupture explosively.

Description

The power supply is a product of up-to-date , microprocessor-controlled
switched-mode power supply technology. This technology permits high output
together with low weight and small dimensions. By using high-quality
electronics, the device operates with high efficiency. Automatic charging
affords protection and prevents harmful battery overload. This considerably
extends the life of the battery. Once connected to the battery and the mains, the
power supply is ready for operation.
The power supply is designed for parallel operation and buffer operation. At all
times, consumers can remain connected, be added or switched off. Consumers
are supplied with the power and the battery is charged at the same time.
Consumer current should be lower than the maximum charging current,
otherwise the battery will not be charged.
If the power supply is operated together with a temperature sensor for the
supply battery (battery II), the power supply controls the charging voltage
automatically depending on the battery temperature. This ensures a particularly
effective and gently charging process for the battery. When not using a
temperature sensor, the power supply controls the charging process as if the
battery temperature was 20° C.
The device is designed for operation in ambient temperatures of up to 35° C. If
the temperature inside the device rises due to a lack of air circulation or due to