Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical System; Start-Up; Maintenance; General - Concept Sanifox Originalbetriebsanleitung

Wc-hebeanlage
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

This will avoid that waste water will flow back into the
tank in case excess water (e.g. heavy rain) is in the sewer.
Install the pressure pipe directly to the next soil stack.
Please check again all connections and make sure that
they are sealed. To prevent a freezing of the discharge
pipe please isolate the complete discharge pipe up to the
sewer level.

5.3. Electrical system

Beware of electrical current!
Incorrectly performed electrical work can result in
fatal injury. This work may only be carried out by a
qualified electrician.
The voltage required in the technical data sheet must
correspond to the existing line voltage.
Make sure that the electrical installations are in ac-
cordance to electrical standard safety regulations
applying in your country.
The lifting stations require no additional motor protection.
The device is connected to the mains with the plug.
It is to ensure that the data specified on the type plate
correspond with the existing power supply.

5.4. Start-Up

Never let the pump run dry for a long time of period,
as it will destroy the pump (danger of overheating).
Now connect the unit with the power cable, to the main
supply and the unit is ready for operation. In combination
with the flat switch the pump starts and stops according
to the liquid level in the tank.
20 | EngliSH

6. Maintenance

6.1. General

The entire system must be checked and serviced at reg-
ular intervals.
The following points should be noted:
Only maintenance work and activities listed here may
be carried out.
All maintenance, inspection and cleaning work on
the system must be carried out in a safe work space
with utmost care. The machine must be disconnect-
ed from the mains power supply for any work to be
carried out. An unintentional switching on must be
avoided.
Electrical work on the machine and the system must
be performed by qualified personnel.
In the event of flammable solvents and cleaning
agents being used, open fire, naked lights and smok-
ing is prohibited.
Ensure that the necessary tools and materials are
available. Order and cleanliness guarantee safe and
trouble-free work on the machine. Remove used
cleaning materials and tools from the machine after
completing the work. Keep all materials and tools in
their designated places.
A trial run or functional test of the machine must only
be carried out under the general operating conditions!

6.2. Maintenance dates

Semi-annually:
Visual inspection of the power supply cable
Cleaning of the container

6.3. Maintenance work

Visual inspection of the power supply cable
The power supply cable must be examined for bubbles,
cracks, scratches, abrasions and / or pinching points.
Upon detection of damage, the damaged power supply
cord must be replaced immediately.
The cable may only be replaced by the manufactur-
er or an authorized or certified service workshop. The
machine may not be put into operation again until the
damage has been properly fixed!
Cleaning of the container
First, disconnect the container from the mains power sup-
ply. Then remove the top by unscrewing the four screws
(under the covers in the corners) of the lifting system.
Thoroughly rinse the container with clean water. Then
close the container with the four screws.