Help in case of malfunction
10 HELP IN CASE OF MALFUNCTION
DANGER!
Danger of electric shock.
When working on the pump, there is the risk of receiving an
electric shock.
■
Disconnect the mains plug before correcting any malfunc-
tions!
■
Faults in the electrical system must be rectified by a quali-
fied electrician.
Malfunction
"Power" LED does not
light up
"On" LED does not light up
"Power" LED lights up, "On"
LED is not lit
"Power" LED and "On" LED
light up
"Failure" LED lights up
NOTE
In the event of other malfunctions, please refer to the operating manual of the connected
pump. In the event of faults that you cannot rectify, please contact our Customer Service de-
partment.
11 GUARANTEE
We will resolve any material or manufacturing faults on the appliance during the legal warranty period
for claims relating to faults, in accordance with our choice either to repair or replace. The legal warranty
period is determined by the legislation of the country in which the appliance was purchased.
467363_e
Possible cause
No mains power.
Fault in the electronics.
Pressure line clogged.
Tapping point is higher than 15
m.
Lack of water on the suction
side.
Pump impeller is blocked.
Thermal protection device of
the pump has tripped.
Fault in the electronics.
Lack of water.
Remedy
Check the power supply or have it
checked by a qualified electrician.
Contact Customer Service.
Check the pressure line.
Reduce the tapping height.
Check suction-side connections and
water level.
Clean the pump.
Press "RESET" button (8).
Contact Customer Service.
Check the pump and suction line
and carry out commissioning.
19