4 . N ot e s
- This unit is short circuit prot ect ed. I f a short circuit should occur, t urn t he power supply off and solve
t he problem .
- I nst all or st ore t he device in a clean and well- vent ilat ed environm ent .
- Do not t ry t o open t he housing yourself. All repairs should be execut ed by a qualified t echnician.
- Disconnect t he unit from t he m ains during m aint enance.
- The unit can get very hot when you are using a high power out put .
- I f t he unit is defect ive, t he out put m ay rise over t he m axim um rat ed volt age. Always keep an eye on
t he load t o prevent dam age.
- This unit should be eart hed properly.
5 . Technica l Specificat ions
input voltage
output voltage
output current
ripple and noise
supply regulation
load regulation
accuracy voltage
accuracy current
protection
operating tem perature
operating hum idity
operat ing at m ospheric pressure
autonom y
dim ensions
weight
Use t h is de vice w it h or igin a l a cce ssor ie s on ly. Ve lle m a n n v ca n n ot be h e ld re spon sible in t he
e ve n t of da m a ge or in j u r y r e sult e d fr om ( in cor r e ct ) u se of t h is de vice . For m or e in fo
conce r ning t his pr oduct , ple a se visit our w e bsit e w w w .ve lle m a n.e u. The infor m a t ion in t his
m a nua l is subj e ct t o cha nge w it hout pr ior not ice .
© COPYRI GH T N OTI CE
Th is m a n u a l is copyr igh t e d. The copyr igh t t o t h is m a n u a l is ow n e d by Ve lle m a n n v. All
worldwide right s reserved. No part of t his m anual m ay be copied, reproduced, t ranslat ed or reduced t o
any elect ronic m edium or ot herwise wit hout t he prior writ t en consent of t he copyright holder.
16.10.2009
PS1 5 0 3 SB
220 VAC ± 10 % ; 50 Hz ± 2 Hz
0 ~ 15 V cont inuously adj ust able
0 ~ 3 A cont inuously adj ust able
CV ≤ 1.0 m V RMS
CC ≤ 3 m A RMS
CV ≤ 1 x 10
- 4
+ 0.5 m V
CC ≤ 2 x 10
- 3
+ 6 m V
CV ≤ 1 x 10
- 4
+ 2 m V
- 3
CC ≤ 2 x 10
+ 6 m V
± 1 % + 2 digit s
± 2 % + 2 digit s
current - lim it ing
0 ~ 40° C
< RH 80 %
86 kPa ~ 104 kPa
8 hrs of cont inuous operat ion
225 x 95 x 160 m m
2.5 kg
4