7.1 Top-hat rail mounting
Simply clip the device onto the top-hat rail (EN 50 022) (see
Fig. 5).
Fig. 5. Mounting on top-hat rails 35 ×15 or 35×7.5 mm.

7.2 Wall mounting

Drill 2 holes of approx. 4.5 mm diameter in the wall or panel
as shown in the drilling pattern (Fig. 6).
Fig. 6. Drilling pattern.
(8)
(13)
(14)
(13)
(15)
(8)
Fig. 7. Rear of device.
(8)
Screw hole brackets
(13) Top-hat rail clips
(14) Rubber buffers
(15) Latch for pulling the screw hole brackets out
(16) Latch for pushing the screw hole brackets in
20
The wile pressing the latch (15) in the base of the device
(Fig. 7, left), pull out the amplifier securing brackets.
Now secure the instrument to the wall or panel using two
4 mm diameter screws.
Note:
To return the brackets to their original positions, the latch (16)
in the base of the devices has to be depressed before applying
pressure to the securing brackets (8) (see Fig. 7, right).

8. Electrical connections

The electrical connections are made to screw terminals which
are easily accessible from the front of the instrument (see Fig.
9) and can accommodate wire gauges up to 1 × 2,5 mm
Terminals:
1 6
2 7
S I N E A X
SV 824
1
2
ON
(8)
3
8
13
4
9
14
5 10
View with
transparent cover
housing
S1, S2 = Signal inputs for channels I and II
A1, A2 = Output contacts for channels I and II
H
Fig. 8. Terminal allocation.
(16)
(8)
+
S1
1
6
+
S2
2
7
5 10
H
+
= Power supply
Make sure that the cables are not live when
making the connections!
The 230 V power supply and 250 V contact
output is potentially dangereous
.
2
Relay 1
Relay 2
4
9 14
3
8 13
A1
A2