Stripping length of the connecting cable
RAS-107SAV Series
Terminal
block
Connecting
cable
RAS-137SAV Series
Terminal
block
Connecting
cable
Model
Power source
Maximum running current
Plug socket & fuse rating
Power cord
Electric parts
cover
When two indoor units are installed in the separated rooms, it is not
necessary to change the selector switches.
• When two indoor units are installed in the same room or adjacent two
rooms, if operating a unit, two units may receive the remote control
signal simultaneously and operate. In this case, the operation can be
preserved by setting either one indoor unit or remote control to B set-
ting. (Both are set to A setting in factory shipment.)
• The remote control signal is not received when the settings of indoor
unit and remote control are different.
• There is no relation between A setting/B setting and A room/B room
when connecting the piping and cables.
Remote Control A-B Selection
To separate using of remote control for each indoor unit in case of 2 air
conditioner are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHK] button on the Remote Control by the tip of the pencil.
"00" will be shown on the display.
1110251210-EN.indd 7
1110251210-EN.indd 7
Downloaded from
www.Manualslib.com
1 2 3
1
2
3
L
N
60
45
Earth line
Power
cord
Connecting cable
1 2 3
1
2
3
L
N
40
30
Earth line
Power
cord
Connecting cable
RAS-107SKV Series
50Hz, 220 – 240 V Single phase
60Hz, 220 – 230 V Single phase
8A
25A
H07RN-F or 245 IEC66 (1.5 mm
Gas Leak Test
Check places for
the indoor unit.
Valve cover
• Check the fl are nut connections
for the gas leak with a gas leak
detector or soap water.
Check places for
the outdoor unit.
Setting of Remote Control
Selector Switch
Remote control selector switch
manuals search engine
CAUTION
• Wrong wiring connection may cause some electrical parts burn out.
L N
• Be sure to comply with local cords on running the wire from indoor unit
to outdoor unit (size of wire and wiring method, etc.).
• Every wire must be connected fi rmly.
50
• This installation fuse (25A) must be used for the power supply line of
40
this air conditioner.
• If incorrect or incomplete wiring is carried out, it will cause an ignition or
Earth line
smoke.
Power cord
• Prepare the power supply for exclusive use with the air conditioner.
• This product can be connected to the mains.
L N
Connection to fi xed wiring: A switch which disconnects all poles and
has a contact separation of at least 3 mm must be incorporated in the
fi xed wiring.
40
30
NOTE
Earth line
• Wire type : More than H07RN-F or 245 IEC66
Power cord
RAS-137SKV Series
11A
2
or more)
OTHERS
OTHERS
4. Press [MODE] during pushing [CHK]. "B" will show on the display and "00"
will disappear and the air conditioner will turn OFF. The Remote Control B
is memorized.
Note : 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A have not "A" display.
3. Default setting of Remote Control from factory is A.
To switch the TEST RUN (COOL) mode,
press RESET button for 10 seconds.
(The beeper will make a short beep.)
This product is designed so that, after a power failure, it can restart automatically
in the same operating mode as before the power failure.
Information
The product was shipped with Auto Restart function in the off position.
Turn it on as required.
How to set the Auto Restart
• Press and hold the RESET button for about 3 seconds. After 3 seconds, the
electronic beeper makes three short beeps to tell you the Auto Restart has
been selected.
• To cancel the Auto Restart, follow the steps described in the section Auto
Restart Function of the owner's manual.
7
: Connecting cable
"B" Display
"00" Display
PRESET
FAN
Test Operation
RESET button
Auto Restart Setting