5.7 KEYPAD UNLOCKING
Make sure the appliance is working (5.1).
Hold down buttons
The keypad is enabled.
6.0 SENSORS
The appliance features two NTC temperature sensors: one measures the temperature inside the
compartment and the other the temperature of the evaporator.
The second sensor has been fitted so that fan operation is optimized and defrosting times shortened.
7.0 DEFROSTING
During operation, frost forms on the surface of the evaporator: this is normal but it reduces evaporator
efficiency. The purpose of defrosting is to eliminate frost and restore full efficiency.
7.1 AUTOMATIC DEFROSTING
The defrosting process is automatic and takes place at preset intervals.
The purpose of the evaporator sensor is to produce the utmost efficiency and shorten defrosting times by
measuring the end-of-defrosting temperature.
The time taken can vary depending on how much frost there is.
7.2 MANUAL DEFROSTING
This mode should be used only when further defrosting is required in addition to that performed
automatically by the appliance.
Make sure the appliance is working (5.1).
Hold button
down for a few seconds.
LED
comes on.
The defrosting cycle stops automatically. How long it takes depends on how much frost there is on the
surface of the evaporator.
Once defrosting has finished, the appliance resumes normal operation.
8.0 CONDENSATION EVAPORATION
The appliance features a system for the automatic collection and evaporation of water produced by
defrosting.
9.0 MINIMUM AND MAXIMUN TEMPERATURE
You can view the maximum or minimum temperature recorded. This feature allows you to check that products
are being stored properly when the business has been closed for a period and hence the appliance has not
been monitored.
9.1 VIEWING MAXIMUM TEMPERATURE RECORDED
Press key
the display reads "hi" followed by the maximum temperature value recorded.
and
together until the message "POn" flashes on the display.
19