Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; Maintenance-Chart; Engine Oil Change - Zipper Maschinen ZI-STE6700DH Betriebsanleitung

Vorschau ausblenden Andere Handbücher für ZI-STE6700DH:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

If the voltage (see voltmeter) is too high or too low, adjust the speed level. If a problem occurs,
stop the generator and take care of the problem.
At the DC-module (12V), a maximum amount of 8.3 A current is possible.
Pay attention to correct connecting:
Red connection: + terminal
Black connection: - terminal
14

MAINTENANCE

The machine is low-maintenance. It contains only a few parts, which have to be maintained
regularly by the operator. Malfunctions or defects that could impair the safety of the machine must
be repaired immediately.
Hot surfaces and rotating machine parts while the engine is running can cause serious
injury or even death. Always stop the machine before carrying out any conversion,
adjustment, cleaning or maintenance work and secure it against unintentional
restarting and wait until the machine has cooled down
14.1

Maintenance-chart

Please maintain the generator in specified months or hours whatever comes first.
Check tank, refuel if
necessary
Check engine oil level,
refill if necessary
Check for loss of fuel
or oil
Check for loose or
missing screws
Changing of oil
Changing of fuel
Cleaning the air filter
Cleaning the fuel filter
Check fuel line,
replace if necessary
Check battery
1. If used in dirty places, the generator should be maintained more regularly.
2.
If the user does not have the right tool, or has too little knowledge, maintenance should be
performed by a qualified person.
14.1.1

Engine oil change

Changing the oil is easier when the engine is still warm.
Remove the oil outlet screw.
ZIPPER MASCHINEN GmbH
www.Zipper-Maschinen.at
ZI-STE6700DH & ZI-STE7500DSH
C A U T I O N
W A R N I N G
Before any
After 1. month or
use
after first 20
operating hours
О
O
O
O
N O T I C E
Engine oil is toxic and must not be released into the environment! Follow the
instructions of the supplier and, if necessary, contact your local authorities
for information on proper disposal.
N O T I C E
After 3 month or
every 100
operating hours
(O)
O
(O)
1 x every month
MAINTENANCE
After 6 month or
every 500
operating hours
O
O
O
O
25

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Zi-ste7500dsh

Inhaltsverzeichnis