LOCK-RELEASE TIMMING
There are two programmable lock-release activation times:
- Lock-release time set from the residence.
- Lock-release time set from the exit button (connected to the 'BS' and '-' terminals).

BUTTON Panel Programming

Carry out the following steps:
1.
With the power supply disconnected, short circuit the «Bs» and «-» (negative) amplifi er terminals,
(or press the exit button when one exists).
2.
Maintaining the aforementioned short-circuit connects the power supply (at this point it will no
longer be necessary to maintain the short circuit or hold down the button). At this time the
amplifi er will generate as many ''beeps'' as seconds programmed for the opening time from
the residence.
2.1.If you want to change this value, you must press any call button as often as the seconds
you wish to program.
2.2.If you do not want to change, just wait 5 seconds without pressing any call button.
3.
Then
the amplifi er will ''beep'' for every second the opening time has been programmed from
the exit button.
3.1.If you want to change this value, you must press any call button as often as the seconds
you wish to program.
3.2.If you do not want to change, just wait 5 seconds without pressing any call button.
4. Exit Programming:
To exit programming mode, wait 5 seconds without pressing any key. A «beep beep» tone will
sound to indicate that you have exited time programming mode.
Notes:
• Values:
- Lock-release time: 01..99 sec. (Default: 03).
- Exit button time: 00..99 sec. (Default: 06).
• On mixed panels with buttons and keypads this method is not permitted and changes must be made via the keypad..
You can also program opening times, along with the other amplifi er parameters, with:
a) VOICE ASSISTED programming
b) Programming with a KEYPAD
To enter the numeric values you must temporarily connect a keypad ref. 7439. The keypad and
amplifi er connection is explained in the manuals.
See instructions via the QR codes on the back of the amplifi er or at www.fermax.com:
- 970064 ANNEX Voice assisted confi guration in button panels.