Herunterladen Inhalt Inhalt Diese Seite drucken

Left Connector Panel - Sony PFM-500A1WU Bedienungsanleitung

Flat panel monitor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 70

Left Connector Panel

Downloaded from
www.Manualslib.com
MONITOR OUT
AUDIO
R
L
1
VARIABLE
CONTROL S
2
IN
OUT
SPEAKERS
(6-16 Ω)
+
+
3
R–
L
SERVICE CODE
8. 8 .
4
AC IN
5
manuals search engine
1 MONITOR OUT AUDIO (L/R) jacks (phono
type)
Output the signal input from the AUDIO IN jacks.
Connect to the audio inputs of an audio amplifier (not
supplied).
Note
These jacks are variable outputs. Set the volume to
maximum position to set the output level to
500 mVrms.
2 CONTROL S IN/OUT jacks (mini jacks)
Connect to the CONTROL S jacks of video equipment
or another monitors. Then you can simultaneously
control all equipment with a single Remote
Commander.
To control equipment by aiming the supplied Remote
Commander to the remote control detector of the
monitor, connect the CONTROL S OUT jack of the
monitor and the CONTROL S IN jack of other
equipment.
Notes
• If you connect the CONTROL S IN jack to the other
equipment's CONTROL S OUT jack, you cannot
operate the monitor with the Remote Commander.
• You can use the stereo cable with mini plug instead
of the control S cable.
3 SPEAKERS L/R terminals
Connect to speakers with 6 to 16 ohms impedance.
Note
Do not connect the speaker's cord to the monitor and
to an amplifier simultaneously, or an excessive electric
current might flow from the amplifier and damage the
monitor.
4 SERVICE CODE indicator
This indicator is only for qualified personnel.
5 ⁄AC IN socket
Connect the supplied AC power cord to this socket and
to a wall outlet. Once you connect the AC power cord,
the monitor turns to standby mode.
11