I Setting the Fan Speed
• Press 4 to select:-
FAN
– Low Fan Speed
FAN
– Medium Fan Speed
FAN
– High Fan Speed
AUTO
FAN
– Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
I Vertical Airflow Direction
G Manual Operation
• Press and hold the Manual Airflow Direction
Selection Button 5 , then release the button at
the desired airflow direction.
• Cooling / Soft Dry/
Heating (for Heat-Pump Model only)
The airflow direction can be adjusted as desired
by using the remote control. This is effective
when you want to cool yourself directly, such as
when coming out of the bath. The louver can be
adjusted within a range between the horizontal
and 25 degrees downward at Cooling and Soft
Dry Operation, and between the horizontal and
45 degrees downward at Heating Operation.
(for Heat-Pump Model only)
Horizontal
Downward
Downloaded from
www.Manualslib.com
G Automatic Operation
• Press the Auto Airflow Direction Button 6.
• Cooling / Soft Dry
The louver will automatically swing up and down
to create the feeling of a refreshing breeze.
• Heating (for Heat-Pump Model only)
When the discharge air temperature is low such
as at starts of heating operation, the air blows at
horizontal level.
As the temperature rises, the hot air blows in a
downwards direction.
manuals search engine
I Setting the Horizontal Airflow Direction
• Adjust it manually
G Use this air conditioner under the following
conditions:
Cooling Model
Indoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
Maximum Temperature
32
23
Minimum Temperature
16
11
Heat Pump Model
Indoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
Maximum Temperature-Cooling
32
23
(Maximum Temperature-Heating)
(30)
(-)
Minimum Temperature-Cooling
16
11
(Minimum Temperature-Heating)
(16)
(-)
G Notes
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.0 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
(Unit in °C)
Outdoor
DBT
WBT
43
26
16
11
(Unit in °C)
Outdoor
DBT
WBT
43
26
(24)
(18)
16
11
(-5)
(-6)
6