Figure 2. Standard Wiring
ALIGNMENT TAB
CONTROL DATA
POWER
J4
F1 1.6A 250V
F1
LED POWER INDICATOR
REMOVABLE TOP PLATE

SPECIFICATIONS

WEIGHT : 5.5 lbs. (2.50 kg) WITH CAMERA
POWER REQUIREMENTS AT DOME: 24VAC, 50/60 Hz, 1.1A
NOTES:
1. TERMINAL STRIPS ACCEPT 18-22AWG WIRE
IF LARGER OR SMALLER WIRE IS REQUIRED, 18-22AWG MUST BE SPLICED
ONTO FIELD WIRE BEFORE INSERTING INTO TERMINAL STRIP.
2. ALL DIMENSIONS IN PARENTHESES ARE IN MILLIMETERS.
3. POWER SOURCE MUST BE SUFFICIENT ENOUGH TO MAINTAIN
A 21.6VAC INPUT AT DOME.
24 VAC POWER @1.1A
AWG
MAX. DISTANCE TO DOME
22
65 FEET (19 METERS)
20
100 FEET (30 METERS)
18
160 FEET (48 METERS)
16
260 FEET (79 METERS)
14
420 FEET (128 METERS)
12
650 FEET (198 METERS)
4. DATA CABLE SHIELD NOT CONNECTED AT DOME.
Rev 1.01
CABLE CLAMP
ALIGNMENT TAB
TERMINAL STRIP TB1
TERMINAL STRIP TB2
TB1-1
24Vac
TB2-1
TB1-2
Ground
TB2-2
ALARM TERMINAL
TB1-3
24Vac
TB2-3
STRIP
TB1-4
RX -
TB2-4
TB1-5
RX+
TB2-5
TB1-6
TX+
TB2-6
TB1-7
TX -
TB2-7
VIDEO BNC
TB1-8
No Connection
TB2-8
CONNECTOR
Jumper W1
Terminated
Position 1 and 2 Last Dome on Data Loop
Unterminated Positions 2 and 3 All Intermediate Domes on Data Loop
Jumper W2
Positions 2 and 3 All Domes
Jumpers W3 & W4
2-wire
Positions 1 and 2 All Domes
ALIGNMENT TAB
TB1
SEE NOTES 1 & 2
Alarm 1
Common
Alarm 2
W1
Common
Alarm 3
Common
W2
Alarm 4
Common
TB3
SEE NOTES 1 & 2
W4
SW1
W3
Jumper W1
Terminated
Unterminated
Jumper W2
Jumpers W3 & W4
UTP
Not Used
To use the board as standard (video over coax and 2-wire R 485):
Jumper W3
Jumper W4
SPECIFICATIONS
WEIGHT : 5.5 lbs. (2.5 kg) WITH CAMERA
POWER REQUIREMENTS AT DOME: 24VAC, 50/60 Hz, 1.1A
NOTES:
1.
TERMINAL STRIPS TB1 & TB3 ACCEPT 18-22 AWG WIRE
TERMINAL STRIP TB2 ACCEPTS 12-18 AWG WIRE.
IF LARGER OR SMALLER WIRE IS REQUIRED, AN APPROPRIATE AWG MUST BE SPLICED
ONTO FIELD WIRE BEFORE INSERTING INTO TERMINAL STRIP.
2.
IF VIDEO IS ON UTP CABLE, BNC CONNECTOR IS NOT USED.
3. ALL DIMENSIONS IN PARENTHESES ARE IN MILLIMETERS.
4. POWER SOURCE MUST BE 24VAC
24 VAC POWER @1.1A
AWG
22
20
18
16
14
12
5. DATA CABLE SHIELD NOT CONNECTED AT DOME.
2
www.honeywellvideo.com
HVSsupport@honeywell.com
Figure 3. Unshielded Twisted Pair (UTP) Option Wiring
CABLE CLAMP
ALIGNMENT TAB
TB2
SEE NOTE 2
BNC CONNECTOR
DATA OVER COAX (UTC) OPTION
VIDEO & DATA
SEE NOTE 2
TERMINAL STRIP TB1
TB1-1
TB1-2
TB1-3
TB1-4
TB1-5
TB1-6
TB1-7
TB1-8
0-300
300-600
REMOVABLE TOP PLATE
600-900
900-1200
1200-1500
Position 1 & 2 Last Dome on Data Loop
* Use lowest switch setting possible.
Position 2 & 3 All Intermediate Domes on Data Lo op
Ex: If cable run is 900 feet, use 600-900 switch setting.
Positions 2 & 3 All Domes
Positions 1 & 2
Positions 2 & 3
S
Positions 1 & 2
Positions 2 & 3
±
10% AT POWER SUPPLY.
MAX. DISTANCE TO DOME
65 FEET (19 METERS)
100 FEET (30 METERS)
160 FEET (48 METERS)
260 FEET (79 METERS)
420 FEET (128 METERS)
650 FEET (198 METERS)
TERMINAL STRIP TB2
Alarm 1
TB2-1
24VAC
Ground
TB2-2
GND
Alarm 2
TB2-3
24VAC
Gnd
TERMINAL STRIP TB3
RX-
TWISTED PAIR
RX+
TX+
TB3-1
Video +
TX-
TB3-2
Video -
DIP Switch
SW1*
Control & Video Over CAT5
CAT5 Cable
Switch Position
Feet
Meters
1
2
3
4
0-90
Off
Off
Off
Off
90-180
On
Off
Off
On
180-270
Off
On
Off
Off
270-365
Off
Off
On
Off
365-455
Off
Off
Off
On
Make sure only one switch is set to ON.