WIRELESS
For configuration, please follow the instructions below, taking into consideration that the first
unit installed will be the MASTER and all the others in sequence SLAVE OPPOSITE to
MASTER and SLAVE SAME AS MASTER UNIT.
WARNING: the MASTER is the only unit receiving commands from control device, that will
detect the ambient conditions through the sensors and thus controlling all the system.
In case of large indoor space or systems on multi-floors, it is recommended to split the
st
nd
system into zones (living area-sleeping area or 1
floor-2
floor) for easier control of the
units.
After setting the single units, it is necessary to create one coding common to all the systems
so that the units interact among them avoiding any interference with adjacent systems.
In the scheme below see the 6 dip switches 0/1 needed to create one coding for each
system.
WARNING: factory setting of dip switches is 0 (OFF), thus recommended to set on 1 (ON)
at least one of the dip switches to uniquely codify the system.