Ventilation
EcoSmart™ Fires do not require any form of permanent fixture or fitting, such as a flue for ventilation, a
permanent connection or any kind of fixed utility for fuel supply.
Denatured Ethanol* is safe to burn indoors without venting, because its main by-products are carbon dioxide,
water steam and heat.
In a house of typical construction, that is, one that is not of unusually tight construction due to heavy insulation
and tight seals against air infiltration, an adequate supply of air for combustion and ventilation is provided through
infiltration. However, if the heater is used in a small room where less than (A) of air space is provided for each
(B) per hour of heater rating (considering the maximum burner setting), the door(s) to adjacent room(s) should
be kept open or a window to the outside should be opened at least (C) to guard against potential build up of
indoor air pollution. Do not install or operate in a bathroom or any other small room.
Burner Kits
Burner One
Burner Two
XL900 Burner
XL700 Burner
Around Burner
Triple Burner
Multiple Burners may be installed into a fireplace setting however the ventilation requirements must be
adhered to at all times.
manuals search engine
(A)
(B)
Cubic Meter m
BTU
3
Cubic Feet [ft
]
3
5.7
1000
[200]
5.7
1000
[200]
5.7
1000
[200]
5.7
1000
[200]
5.7
1000
[200]
17.1
3000
[604]
(C)
Minimum room size
Metric mm
Imperial [in]
25.4
The room cannot be less than 70m
[1]
[2472ft
] per burner.
3
25.4
The room cannot be less than 25m
[1]
] per burner.
[1000ft
3
The room cannot be less than 110m
25.4
] per burner.
[1]
[3884ft
3
25.4
The room cannot be less than 100m
[1]
[3531ft
] per burner.
3
25.4
The room cannot be less than 70m
[1]
[2472ft
] per burner.
3
76.2
The room cannot be less than 210m
[3]
[7416ft
3
].
www.ecosmartfire.com