Clearances & Installation
Clearances &
Installation
Downloaded from
www.Manualslib.com
The installation & clearances guidelines below are provided as a general overview only. Detailed installation
specifications are available for each individual model of the EcoSmart™ Fire range and should have been
referred to and taken into account prior to your purchase. To ensure the installation complies with our
Compulsory Installation & Clearance Requirements please contact The Fire Company Pty Ltd or one of its
representatives for a copy of the relevant specification to be sent to you.
The Around Burner is primarily intended for outdoor use. All other Burners are primarily intended for indoor use,
however when any Burner is used outdoors, it is important that the Burner be positioned in a large open space
ensuring that the nearest combustible (trees, branches, umbrellas, ceilings etc) are a minimum of 2000mm
[78.74in] away in all weather conditions (for example, on windy days where there is movement in branches,
the clearance must still be met). When not in use it is recommended that you protect the model from water
damage or corrosion by covering. Burner Covers are available. When used indoors, ensure that the mouth
of the flame is positioned a minimum of 1500mm [59.1in] away from curtains, flammable materials and other
sources of ignition. Be aware of drafts.
Clearances
INSERTING WITHIN A FIREBOX SETTING
The EcoSmart™ Burner can only be fitted into a firebox that has minimum clearances as outlined below.
Burner Kits
Metric mm / Imperial [in]
Burner One &
Burner Two
XL900 Burner
XL700 Burner
Around Burner
Triple Burner
Custom made fireboxes must:
- be made out of a non-combustible material such as stainless steel;
- be constructed to accommodate a Top Tray or "Twin Skin" (NOTE: Not applicable for the Around Burner);
- have built in spacers of 20mm [0.8in] on all sides to ensure that it does not sit directly against any
combustible materials and an air gap is incorporated for insulation around the box construction.
The Fire Company Pty Ltd is not liable for any injuries or damages sustained through the use of
custom made or privately commissioned Fireboxes.
Burner One & Burner Two
XL900 Burner
manuals search engine
Firebox Width
Firebox Depth
650
365
[25.6]
[14.4]
1100
350
[43.3]
[13.78]
900
350
[35.4]
[13.78]
650
365
[25.6]
[14.4]
1200
500
[49.6]
[19.7]
Around Burner
XL700 Burner
ENGLISH
Overhead
Rear
650
30
[25.6]
[1.2]
500
40
[19.7]
[1.6]
500
40
[19.7]
[1.6]
650
30
[25.6]
[1.2]
750
40
[29.5]
[1.6]
Triple Burner
www.ecosmartfire.com
Front
45
[1.8]
50
[2.0]
50
[2.0]
45
[1.8]
65
[2.6]
8