Clearances & Installation
INSERTING WITHOUT A FIREBOX SETTING:
When creating a custom built setting the following dimensions must be adhered to at all times.
The Fire Company Pty Ltd recommends using the Burner in a firebox manufactured by The Fire
Company Pty Ltd only. The Fire Company Pty Ltd is not liable for any injuries or damages sustained
through the use of custom made or privately commissioned Fireboxes.
A fire extinguisher is a compulsory accessory.
Burner Kits
Overhead
Metric mm
Imperial [in]
Burner One &
1500
Burner Two
[59.1]
XL900 &
1500
XL700 Burners
[59.1]
2000
Around Burner
[78.7]
1800
Triple Burner
[70.9]
Warning: The rear wall should be a non combustible material.
If the rear wall is combustible, a distance of 600mm [23.6in] must be allowed for.
Burner One & Burner Two
min
[23.6]
600mm
min
[23.6]
600mm
min
[1.8]
45mm
Around Burner
CONVERTING AN EXISTING FIREPLACE:
If inserting an EcoSmart™ Burner into an existing masonry fireplace, utilise the damper within the existing
fireplace in order to keep the heat from escaping through the flue.
manuals search engine
Front
Sides
(Only if Non-combustible)
Metric mm
Metric mm
Imperial [in]
Imperial [in]
45
600
[1.8]
[23.6]
65
600
[2.6]
[23.6]
45
600
[1.8]
[23.6]
65
600
[2.6]
[23.6]
XL900 and XL700 Burners
min
[1.2]
30mm
min
[23.6]
600mm
Triple Burner
Rear
Nearest
Combustible Radius
Metric mm
Metric mm
Imperial [in]
Imperial [in]
30
600
[1.2]
[23.6]
40
600
[1.6]
[23.6]
30
600
[1.2]
[23.6]
40
600
[1.6]
[23.6]