5.3 place of installation

For the minimum distances expressed in cm that
must be respected when positioning the appli­
ance with respect to flammable materials and
objects, refer to the Product booklet delivered as
an attachment with the appliance.
Floors made of flammable material such as wood,
parquet, linoleum, laminate or floors covered
with carpets must be protected by a fireproof
base under the appliance that also protects the
front during cleaning from any falling burning
residues.
The manufacturer declines all responsibility for
any variations in the characteristics of the mate­
rial constituting the floor under the protection.
Set up an accessible technical space
for any maintenance work.
Remember to respect the minimum distance
from flammable materials (X), shown on the
identification plate of the pipes used to make the
chimney (Fig. 6).
pi = Flammable wall
pp = Floor protection
Pi
80 cm
Set up the electricity supply line to arrive near the
appliance for the connection of the power cable.
38
Pi
X
Pp
Fig. 6

5.4 Combustion air

The appliance, during its operation, requires
combustion air.
The inflow of combustion air can be obtained in
the following ways:
• it can come from the installation room or from
suitable adjacent rooms (Fig. 7 ­ Fig. 8)
• it can come directly from outside with direct
connection to the combustion chamber (Fig.
9 ­ Fig. 10).
Extraction of combustion air in the room
Create the air inlet on the wall (Fig. 7 - pA = Air
Inlet), and allow the appliance to take air into the
room.
If the rear wall of the appliance is an external wall,
make a hole for the intake of combustion air at a
height of about 20­30 cm from the ground, re­
specting the dimension indications given on the
technical data sheet at the end of the booklet.
A non­closable permanent aeration grid must
be placed externally; in areas that are particularly
windy and exposed to weathering, provide rain
and wind protection.
Ensure that the air intake is positioned so that it
won't be accidentally obstructed.
If it is impossible to create an external air intake
in the wall behind the appliance (non­perimeter
wall), a hole must be made in an external wall of
the room where the appliance is positioned.
004778300 ­ 14/09/2020
PA
Fig. 7