Herunterladen Inhalt Inhalt Diese Seite drucken

Trouble Shooting; Maintenance; Disposal; Product Label - Cedes TOF/Spot-Safety S Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

TOF/Spot-Safety

13. Trouble shooting

Status
LED off
Object in the
safeguarded area and
LED dimmed red
No object in the
safeguarded area and
LED bright red
The output doesn't
switch after
starting test
The output doesn't
switch back after ending
of test
If the problem persists, please contact your local CEDES
representative (www.cedes.com).

14. Maintenance

Although the TOF/Spot-S does not need regular
maintenance, a periodical functional check is strongly
recommended as follows:
 Check the mounting position and detection area of the
sensor.
 Clean the optical window with a soft towel and a little
soapy water.
NOTICE
Damage to the optical window
 Never
use
or mechanically abrasive towels or
highpressure water to clean the sensors.

15. Disposal

The TOF/Spot-S should only be replaced if a similar
protection device is installed. Disposal should be done
using the most up-to-date recycling technology according
to local regulations and laws. There are no harmful materials
used in the design and manufacture of the sensor. Traces
of such dangerous materials may be found in the electronic
components but not in the quantities that are harmful.
12
Action
 Check supply power
 Check electrical
connections
 Check distance setting
 Check alignment
 Check electrical
connections
 Check distance setting
 Check alignment
 Is an object in the
detection area?
 Check electrical
connections
 Sensor doesn't see a
background
 Is an object in the
detection area?
 Check distance setting
any
solvents,
cleaners

16. Product Label

Each TOF/Spot-S is labelled as below. It contains following
information:
Figure 26:
Product label - TOF/Spot-S
Lot No.:
yymmdd: year (2 digits), month, day
mmmmmmmm: manufacturing job number
eeeee: employee number responsible for final test
cccccc: incremental number

17. Technical data

Optical
Operating range
- Types P, T and I
- Type N
Active light spot at 2 m distance 20 mm × 20 mm
Switching level
- Type T
Measurement precision
Mechanical
Dimensions
Housing material
Housing color
Enclosure rating
Operating temperature range
Relative humidity
(non-condensing)
Electrical
Supply voltage U
SP
Current consumption at 24 VDC 50 mA
Peak current consumption
during power-up at 24 VDC
Outputs
Max. switching voltage
Max. switching current
Max power-up time
Max. response time
Test response time
English
0.2 ... 6 m (0.7 ... 20 ft)
0.2 ... 3 m (0.7 ... 10 ft)
(0.79 in × 0.79 in
at 6.5 ft)
0.15 m (5.9 in)
from background
±5% at 2 m (at 6.5 ft)
±10 cm (3.93 in)
over the whole range
Ø 29.5 × 35.8 mm
(1.16 × 1.41 in)
Polycarbonate
Black
IP65
−40 °C... +60 °C
0 ... 95%
10 ... 30 VDC
500 mA
Solid-state relay or
dynamic universal
40 V
150 mA
1 s
60 ms
5 ms
© CEDES | V 4.0

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis