Installing the System in the Rack
1 Pull the two inner slide rails out of the rack until they lock in the fully
2 Lift the system into position above the extended slides.
3 Lower the back of the system while aligning the back shoulder screws
4 Engage the back shoulder screws into their respective J-slots.
5 Lower the front of the system and fit the middle and front shoulder screws
6 Press the slide-release latch on the outside of each inner slide, then push
7 Install the cable-management arm. See "Installing the Cable-Management
8 Tighten the thumbscrews on the rack front panel to secure the slide
Downloaded from
www.Manualslib.com
CAUTION:
If you are installing more than one system, install the first system
in the lowest available position in the rack.
CAUTION:
Because of the size and weight of the system, never attempt to install
the system in the mounting rails by yourself.
extended position.
The three shoulder screws on the sides of the system fit into the
corresponding J-slots (see detail on Figure 1-7) on the inner slide
assemblies.
on the sides of the system with the back J-slots on the slide assemblies.
into the J-slots in the slide assemblies.
The system release latch at the front of the inner slide rail will snap back as
the shoulder screw passes into the front slot. Use this system release latch
when you wish to remove the system from the slide assemblies.
the system into the rack.
Arm" on page 19.
assemblies to the rack.
manuals search engine
Rack Installation Guide
17