Appliance dimensions

DA 119
DA 112
52
Downloaded from
www.Manualslib.com
manuals search engine
1) Extraction
2) Recirculation
3) Ventilation grille position for recirculation
Position:
The shaded area represents the wall
or ceiling area for the vent cut-out, and
for fitting the connection socket.
For recirculation mode, only a connection
socket needs to be fitted. The connection
socket is fitted in area a.
Connection for air extraction C 150 mm,
or C 125 mm with reducing collar.
Safety distance between hob and
cooker hood
For safety reasons a minimum safety
distance must be maintained
between the top of the cooker/hob
and the bottom of the cooker hood:
– 450 mm above electric cookers/
hobs
– 650 mm above gas cookers/hobs
– 650 mm above an open grill from
the Miele range.
See the Warning and safety
instructions for further information.
When deciding on the safety distance
between the hob and cooker hood,
please note that
– a distance of 650 mm above electric
cookers/hobs may be preferable to
give more working space under the
hood.
– with a ceiling mounted hood you
must make sure that there is
sufficient space below the hood to
maintain the correct safety distance.