Herunterladen Diese Seite drucken

Dell PowerEdge R910 Systems Informationsaktualisierung Seite 4

Vorschau ausblenden Andere Handbücher für PowerEdge R910 Systems:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 40
Microsoft Windows Server 2003 R2 SP2 (x64)
Edition With SP2 Limitation With 1 TB System
Memory (When Memory RAS Mode is Not Used)
The system does not boot to the operating system with 1 TB of system
memory. To resolve this issue, set the memory RAS mode to sparing or mirror.
After installing the operating system, add a boot time switch mem=1046528
or /burnmemory=2048 in the boot.ini file before disabling the RAS mode
for subsequent boots.
MAC Address Labels
For security reasons, the embedded NIC and iDRAC6 Enterprise MAC
address labels provided with your system cannot be affixed after they have
been removed.
NOTE:
system.
System Limitations With an Optional 10 Gb I/O
Riser
The 10 Gb I/O riser provides two 10 Gb SFP+ ports using a Broadcom
57711 controller in addition to two 1 GbE ports. The following are the
limitations with the 10 Gb I/O riser:
To ensure system power redundancy, the 10 Gb I/O riser requires all four
power supplies to be connected to the AC power source. The system power
becomes non-redundant if one of the power supplies is removed.
CAUTION:
system power becomes non-redundant can lead to a system failure and results in
loss of data.
Wake On LAN (WOL) is not supported on the 10 Gb SFP+ ports due to
Broadcom 57711 design limitations. However, WOL is supported on the
two 1 GbE ports available on the riser.
4
Downloaded from
www.Manualslib.com
The labels are located on the system identification panel on the front of the
A power supply failure or removal of another power supply after the
Information Update
manuals search engine
®

Werbung

loading