BIW1-C/E310/317-M_ _ _ _-P1-SA002-ZA0F
Micropulse Transducer in Profile Housing
EU Directive 2004/108/EC (EMC Directive) and EMC law
Noise immunity: EN 61000-6-1 / EN 61000-6-2
Emission: EN 61000-6-3 / EN 61000-6-4
Conformal use
The BIW transducer is intended to
be installed in a machine or
system. Together with a controller
(e.g. PLC) it comprises a position
measuring system and may only
be used for this purpose.
User's Manual
A detailed standard user's manual
can be obtained on the Internet at
www.balluff.com\downloads-biw
or via e-mail to
service@balluff.de
Mounting brackets and M4 × 20 cylinder head
screws, DIN 912, max. tightening torque 2 Nm
Housing length
Mechanical zero point
Electrical zero point
Electrical stroke = mechanical stroke
Clamp spacing
Nominal length < 300 mm
Nominal length 300 mm to < 600 mm
Nominal length > 600 mm
1
english
Installation
No strong electrical fields
are permitted in the
direct vicinity of the
transducer.
Any orientation is permitted.
Mount the transducer on a level
surface of the machine using the
mounting brackets. Observe the
recommended spacing of the
mounting brackets.
1. Align transducer with sliding
rod.
2. Tighten mounting screws to a
maximum of 2 Nm.
A = Nominal length + 100 mm
B0 = 0 + 2 mm
B0 + 5 mm
B = Nominal length + 10 mm
C = Nominal length - 20 mm
C = Nominal length - 15 mm
C = Nominal length - 10 mm
BIW1-...-M0100-P1-...
Nominal length 100
BIW1-...-M0360-P1-...
Nominal length 360
BIW1-...-M0750-P1-...
Nominal length 750
File No.
E227256
A = 200
B = 110
C = 80
A = 460
B = 370
C = 345
A = 850
B = 760
C = 740

Werbung