Example picture of controller
Parameter Programming
Set Point (SP) is the only parameter the user
can access without code protection.
- Press SET. Out1 on display starts blinking
and SP value will appear on the display.
- The value can be modified with the  and
 arrows.
- Press SET again to accept changes and real
value is shown on the display.
Led indications
"out1" - indicates that the heater is on.
Flashing indicates programming mode.
Display messages
In normal operation, the sensor temperature
will be shown on the display. In case of alarm
or error, the following messages will be
shown:
-
alarm is active
-
Pr1 = Probe Error
 Disconnect and contact service
-
°C /°F = Celsius or Fahrenheit degree
Controller operation
Once the controller reaches set point, the
heater will turn off and will not turn on again
until the temperature falls 5K below the set
point. The controller will alarm if the
temperature at the sensor exceed 15K of the
set point.
Controller version
When
connecting
requirements of the standards listed below in
"General Safety Instructions" and "Additional
Safety Instructions" have to be observed. The
maximum
operating
temperature for the product are listed in the
technical data section.
It has to be ensured that this temperature is
never exceeded at any point of the product,
irrespective of whether it is switched on or
off. In cases in which the kind of installation or
application cannot exclude that the maximum
product temperature is exceeded, a suitable
device for temperature control and, if
necessary, for temperature limitation has to
be provided. Proper operation of the
temperature controlling and limiting devices
has to be checked at initial operation.
Desizing
Owing to technical reasons, some smoke or
vapors will develop at certain heating
temperatures during initial operation of
polymer and glass-fiber fabric materials. This
is caused by the heat-up of the size (slipping /
binding or cross-linking agent). The emerging
vapors are harmful and should not be inhaled.
Please permit good ventilation during this
de-sizing phase!
the
product,
the
and
withstand
8 |
P a g e - S e i t e